Model |
UQ1-01 |
UQ1-02 |
Number of occupied I/O points |
32-points, 1 slot |
Sampling period |
Max. 100 μs |
Max. 500 μs |
Communication method (between adjacent units) |
Infrared ray |
Terminal
block |
Usable wire |
Core 0.3 to 0.75 mm2 (outer diameter 2.8 mm or less) |
Usable solderless terminal |
R1.25-3 without sleeve |
Protocol
(Between
UQ1 to
CD5) |
No. of sensor head |
Max. 2 heads |
Max. 2 sensors |
Protocol |
RS-422 |
Baud rate |
921.6 kbps |
256 kbps |
Cable |
DOL-1212-G☐☐M |
- |
Cable extension |
Up to 50 m using an optional extension cable (not included) |
- |
Judgment
output |
I/O terminals |
2 Input / 2 Output |
Mode |
NPN open collector output |
Output voltage |
12 to 24 VDC (±10%) |
Output current |
80 mA (12 to 24 VDC) |
Residual voltage |
2 V or less |
Leak current |
0.2 mA or less |
Protection |
Overcurrent detection circuit |
Trigger
input |
Conditions |
ON when connected to ground |
Voltage |
ON voltage: 1.0 V or less / OFF voltage: 2.0 V or more |
Input impedance |
Approx. 10 kΩ |
Functions |
Sensor head settings, control output,
calculation, various hold functions, filter
function, bank settings, storage function |
Sensor settings, control output, calculation, various
hold functions, bank settings, storage function |
High speed logging point |
Max. 262,144 points |
EEPROM overwriting limit |
Max. 1,000,000 times for same memory area |
5 VDC current consumption |
0.5 A or less |
Noise tolerance |
500 V p-p (simulator), Noise width: 1 μs
Fast transient noise 1 kV (IEC 61000-4-4) |
Insulation resistance |
Min. 10 MΩ (insulation resistance meter) |
Environmental
resistance |
Degree of protection |
IP2X |
Ambient
temperature |
-10 to +55℃ (no freezing or condensation)/
When stored: -20 to +70℃ |
Ambient humidity |
35 to 85% RH / When stored: 35 to 85% RH |
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm;
2 hours in each of the X, Y, and Z directions |
Applicable regulations |
EMC directive (2004/108/EC) |