■ Function module replacement on site without recalibration "plug and measure"
■ Hygienic design according to EHEDG, FDA and GMP recommendations
■ Material and surface quality according to the hygienic requirements
■ Modular pressure transmitter
Output signal:
- 4…20 mA
- HART® protocol (rev. 6), option
- PROFIBUS PA, option
■ Function modules
- Multifunctional display with 5-segment digital display and bar graph
- Switching module with 2 floating channels, maximum 0.5 A switching current, electrically isolated at all sides, without additional auxiliary power
■ Limits of measuring range 0...80 mbar to 0...40 bar
■ Accuracy ≤ 0.15 %
■ Turndown 5:1
■ Degree of protection IP 66, piezoresistive measuring cell directly aerated
Constructional design / case
Process connection
Design: |
See order details |
Measuring system
Sensor: |
Piezoresistive measuring element |
System filling: |
Synthetic oil, free of silicon FD1, FDA listed |
Accuracy
General: |
Limit point setting: |
per DIN 16086 |
|
Reference conditions: |
per EN 60770-1 |
|
Linearity errors: |
≤ 0.15 % of span
TD 5:1 no modification |
|
Hysteresis: |
≤ 0.05 % of nominal range |
|
Repeatability: |
≤ 0.05 % of nominal range |
|
Calibration position: |
Vertical mounting position |
|
Influence of mounting position: |
≤ 3.5 mbar |
|
Long-term drift (EN 60770-1): |
≤ 0.1 % / year of nominal range |
Temperature effect: |
Case: |
|
|
Lower range value / upper range value |
|
|
Range 0…60 °C: |
± 0.15 % / 10K of nominal range |
|
Range < 0 °C, > 60 °C: |
± 0.2 % / 10K of nominal range |
|
Process connection:
(depending on design) |
|
|
Diaphragm seal:
DN 25/1“
DN 32/1 1/2“
DN 40
DN 50/2“
HYGIENIC G1A |
Zero point error:
4.8 mbar/10K
2.3 mbar/10K
1.6 mbar/10K
0.6 mbar/10K
1 mbar/10K |
The specify zero error for the process connection is a guide value for a standard design. We can provide a detailed system calculation upon request. Systems with reduced diaphragm seal errors are also available.
The wetted surfaces made of stainless steel are executed according to EHEDG Doc.8 and ASME BPE SF3 (Code: HY). |
We guarantee the following surface roughness values: |
Diaphragm foil: Ra ≤ 0.38 µm
Laser welds: Ra ≤ 0.76 µm
Turned parts: Ra ≤ 0.76 µm |
Further versions of hygienic design upon request. |
Material: |
Stainless steel mat. no. 1.4435 316L/316 |
Gasket: |
EPDM-FDA listed (in case of flush mounted diaphragm with O-ring) |
Design: |
Two-chamber case design with screw cap. |
|
Minimum case volume, excellent moisture and condensate protection |
Material: |
Stainless steel mat.-no. 1.4301 (304) |
Degree of protection per EN 60529: |
- IP 66
- optional: IP 69K |
Climatic category per EN 60721 3-4: |
4K4H |
Pressure compensation: |
PTFE filter system |
Window: |
Non splintering plastic: Makrolon |
Case seal: |
O-ring: NBR |
El. connection: |
Screw terminal 1 mm² |
Cable gland: |
Cable gland M16,
material: PA |
|
Circular connector M12 |
|
Further cable glands upon request. |
Weight: |
Standard device without diaphragm seal and function modules approx. 0.65 kg |