Specifications of Digital Counters |
Model |
C-500 |
C-700 |
Displayed digits |
|
Selection of 10µm |
|
Selection of 1µm |
Display |
|
-9999.99 -- 00.00 -- 9999.99 |
-999.999 -- 0.000 -- 999.999 |
High-luminance LED display with 7 segments (red) |
|
Power supply voltage
& power consumption |
|
AC100V -- AC240V
/ 9VA or lower |
Operating temperature |
|
0 -- +40ºC |
Compatible Linear Gauges |
|
Selection of 10µm display |
|
Selection of 1µm display |
|
DL-2, D-5, D-10, D-20, D-30, D-50, D-100, DN-10, DN-20, D-5UZ |
DL-2S, D-5S, D-10S, D-20S, D-30S, D-50S, D-100S DN-10S, DN-20S |
|
Accessories |
|
AC power cord (2m) ; One cord |
Metal fittings for panel installation ; Two units |
|
( to be used for installation in panel and securing stand fittings ) |
Stand fittings ; One unit |
|
( to be used when counter is used as desktop device ) |
|
Terminal block functions
( Rear panel ) |
|
Terminal block |
--> Screwless terminal block |
Usable electric cables |
--> AWG22 - 28 |
Length of peeled wire of cables |
--> 8 - 9mm |
Pin alignment |
(*1) |
St/Sp |
Controls "START" and "STOP" of MAX, MIN, P-P
measurement mode. |
(*2) |
React |
Controls "SUSPEND" and "START" of P-P
measurement mode. |
3 |
Latch |
Controls "LATCH" and "CANCEL" of measured value. |
4 |
Reset |
External "RESET"
"PRESET" ( Function available only in Model No. C-700 ) |
5 |
Alarm |
Error signal output |
|
Max
Display |
Min
Display |
P-P
Display |
(*6) |
-NG |
Outputs -NG based on
OK±NG judgment (red LED). |
--> |
+NG(2) |
-NG(1) |
NG(2) |
(*7) |
OK |
Outputs OK based on
OK±NG judgment (green LED). |
--> |
OK |
OK |
OK |
(*8) |
+NG |
Outputs +NG based on
OK±NG judgment (orange LED). |
--> |
+NG(1) |
-NG(2) |
NG(1) |
|
(1) : NG output in first stage
(2) : NG output in second stage |
9 |
GND |
GND |
(* ) |
Circled numbers indicate functions available only in Model No. C-700 |
|
Dip sw setting functions
( Printed circuit board ) |
|
Dip(1) |
|
Dip(2) |
SW 1 |
Select 1µm or 10µm |
|
SW 1 |
Settings by Manufacturer |
SW 2 |
Select direction of
counting. |
|
SW 2 |
Select whether or not to include
default values for OK±NG judgment. |
SW 3 |
Select activation or non-
activation of error output. |
|
SW 3 |
Select either "orthogonal" or "sine"
for input waveform. |
SW 4 |
Select activation or non-
activation of overflow. |
|
SW 4 |
Select either 400msec or 100msec
for RESET time. |
|
Data output (RS-232C)
D-Sub9P plug
INCH screw |
|
Options |
|
Excel input software |
|
BCD output board |
|
Pin Alignment |
1 |
NC |
-- |
|
Communication mode ; Half-duplexasynchronouscommunication |
2 |
Rxd |
in <-- |
|
Communication speed ; 9600bps |
3 |
Txd |
--> out |
|
Format ; 7Bit ASCI I |
4 |
NC |
-- |
|
Parity ; even number |
5 |
SG |
-- |
|
Stop bit ; 1Bit |
6 |
NC |
-- |
|
RTS / CTS ; Returned when not in use. |
7 |
RTS |
--> out |
|
Reception command ; Transmission request ASCI I [T] [t] |
8 |
CTS |
in <-- |
|
; Reset ASCI I [R] [r] |
|
9 |
NC |
-- |
|
Connection cables ; Cross cables ( not included ) |
PK-2002 |
|
; Data imported into Excel cells from RS-232C output. |
CB-BCD |
|
; Cannot be used in combination with RS-232C output. |
|
Display functions |
|
1/1 display |
--> Displays the measured value as is. |
1/2 display |
--> Displays the measured value after halving it. |
×2 display |
--> Displays the measured value after doubling it. |
Note ;
With 1µm display and ×2 display, the lowest digit will be displayed as an even number. |