| Model |
AN50500S(F) |
AN50501S(F) |
AN50502S(F) |
AN50503S(F) |
AN50505(F) |
AN50510(F) |
| Input |
Single Phase
220V±22V,50Hz±5Hz |
3-phase,3-line
380V±40V,50Hz±5Hz |
| Output |
Voltage |
0-60V |
| Current |
0-25A |
0-50A |
0-100A |
0-150A |
0-250A |
0-500A |
| Power |
0-1.5kVA |
0-3kVA |
0-6kVA |
0-9kVA |
0-15kVA |
0-30kVA |
| Display |
|
LCD,4 digits |
| Setting Accuracy |
Voltage |
(15V-60V):≤±1%*reading
(0V-15V):≤±1%*reading±1V |
| Current |
≤±1% (reading+measurement) |
| Read Back Accuracy |
Voltage |
(15V-60V):≤±1%*reading
(0V-15V):≤±1%*reading±1V |
| Current |
≤±1% (reading+measurement) |
Ripple&Noise
20Hz-20MHz |
Vrms |
80mV |
180mV |
280mV |
| Vpp |
300mV |
750mV |
1200mV |
| Power Voltage Effect |
±0.2% |
| Load Effect |
±0.2% |
| Noise |
≤55db(A) |
65db(A) |
≤65db(A) |
≤70db(A) |
| Effciency |
≥ 0.85 |
| Over Load |
100%
110%< rated current, the output will be stopped immediately
|
105%
200%< rated current, the output will be stopped immediately
|
| Protection Function |
Input lack phase protection(three phase);
Output over current/over voltage protection; inverted and short circuit protection;
Over heat protection |
| Transient Response Time |
≤10ms |
| Max. Lead Wire Voltage Drop Compensation |
4V |
| Communication Function |
RS232(standard)/RS485(Optional) |
| Memory Function |
Can preset 10 groups parameters |
| Measurement Function |
5 setting groups and 10 steps sequence,3 working mode for every step, max cycle3000 times |
| Temperature Drifts |
0.04%Vmax/℃ |
| Time Drifts |
0.3%Vmax |
| Working Conditions |
Operating Temperature:0℃-40℃;Operating Humidity:10-95% |
Dimension
W×H×D(mm) |
441×88.9×630
(19 inch standard case, 2U height) |
480×225×620 |
440×600(wheels)×660 |
540×1230(wheels)×670 |
| Weight |
20kg |
55kg |
90kg |
180kg |