- In addition to the ultraviolet rays UVA · UVC, data recording is also possible to connect the K / J-type thermocouple sensor (sold separately) to the temperature measurement / SD card.
- Since the recording data is available in commercially available spreadsheet software, you can take advantage of a variety of applications.
- Data recording, can be selected from the automatic recording / manual recording.
- Sampling set time of automatic data logger can be set arbitrarily than 1,2,5,10,30,60,120,300,600,1800,3600 seconds.
Thông số kỹ thuật
Ultraviolet rays
|
range |
resolution |
Measurement accuracy |
UVA / UVC |
~ 1.999MW 0 / Cm 2 |
0.001MW / Cm 2 |
± (4% FS + 2dgt) |
~ 20.00MW 2.00 / Cm 2 |
0.01MW / Cm 2 |
FS = full scale (full scale)
Recommended to be measured ultraviolet wavelength
type |
wavelength |
UVA sensor |
320 ~ 380nm (calibration ultraviolet wavelength: 365nm) |
UVC sensor |
200 ~ 280nm (calibration ultraviolet wavelength: 254nm) |
Please use to measure the ultraviolet light of the wavelength of each of the sensor is above. UVC sensor ultraviolet wavelengths other than the 200 ~ 280nm to the light to be measured at the time of use were included: If you measure (for example, natural light, etc.), it may not be measured correctly.
Device using the wavelength containing UVA region (an example): tanning bed, reptiles breeding lighting, plate making lamps, black light, etc.
with a wavelength including a region of UVC device (one example): Watching Fish sterilizing filter, athlete's foot ultraviolet light therapy equipment, germicidal lamp, etc.
Temperature
type |
Measurement range |
resolution |
Measurement accuracy |
K type |
-50.0 ~ + 1300.0 ℃ |
0.1 ℃ |
± (0.2% rdg + 0.5 ℃) |
-100.0 ~ -50.1 ℃ |
± (0.2% rdg + 1 ℃) |
J type |
-50.0 ~ + 1100.0 ℃ |
0.1 ℃ |
± (0.2% rdg + 0.5 ℃) |
-100.0 ~ -50.1 ℃ |
± (0.2% rdg + 1 ℃) |
- It does not include the option of sensor accuracy in the measurement accuracy.
- There is no handling of the J-type thermocouple sensor at our company.
General specification
Use temperature and humidity |
0 ~ + 50 ℃, 80% RH or less (without condensation)
|
Storage temperature and humidity |
-20 ~ + 60 ℃, 85% RH or less (without condensation) |
Size |
Body: W68 x H177 x D45mm,
UVA Sensor: probe head φ45 × 32mm, handle φ24 × 125mm, about the time code telescopic 350mm
UVC sensor: φ38 × 27mm, about the time code telescopic 350mm
|
weight |
Body: about 350g (including battery),
UVA · UVC sensor: about 100g
|
Power supply |
AA batteries × 6 or AC adapter (sold separately) |
accessories |
Manual, UVA sensor, UVC sensor |
Proofreading |
Yes |
option |
AC adapter: VSM-932EK
K-type thermocouple sensor: LK model number of the product
|
JAN |
4983621230376 |
About SD card
- It supports commercially available SD card (1 ~ 16GB), but the operation authentication for the SD card product of all manufacturers is not done. Because there may not be accustomed to the use by SD card, please note.
- SD card is not included in the product. Please purchase separately.
- SDXC type of memory card of the card and MMC Nadohoka can not be used.
- SDXC, SDHC is a registered trademark of the SD Association.