- Test set UI-15/225 designed for testing electrical strength of cable insulation AC voltage line frequency, according to the "Rules for Electrical Installation" and RD 34.45-51.300 with a maximum voltage of 15 kV and a load capacity of 225 kVA.
- Overall Rated voltage AC, V : 380 ± 38
- Frequency, Hz : 50 ± 1
- Most output voltage (rms), kV : 15
- Maximum voltage burning, kV : 15
- Short-circuit current to burn, A : 20
- Maximum output power, min, kVA : 225
- Maximum loading capacity, uF (at 7.5 kV) : 6
- Q-factor, min : 15
- Lifting speed of the test voltage, max kV/s (the speed set in the configuration) : 1
- Operating current on the high side, A : 15
- Current consumed on the low side, max, A : 80
- Reduced error meas. voltage, maximum, % : 3
- Continuous operation at maximum power, min : 20
- Consumptionpower, not more, kVA : 30
- Dimensions L × W × H, mm : 2540×1130×2030
- Weight, kg : 2215