Model |
CPV-GAas-30-CP-AR |
CPV-GAas-40-CP-AR |
Exterior dimension |
485 * 600 * 600 mm (W*H*D)(including projected parts) |
Standard Channel |
6 channel / module / 72W (max 30 channel/set) |
5 Channel/module/250W (max 40 channel/set) |
Maximum control Module |
5 module / 360W |
8 module / 2 KW |
Method of Test setting |
Set channel (start/stop) ; each channel single control ,can set different Current & data |
CH. Output volt/current range |
AC 0~4V/ 0~3000mA(1mA/Step)/channel |
AC 0~5V/ 0~10A(1V/Step)/channel |
Operation mode |
CC |
sample rate & com interface |
1Sec~59:59mm:ss (Sample to Controller) , 5sec (Sample to PC) & RS485 or RS232 |
Continuous Mode
ON-OFF Mode |
Select Continuous Mode
Allow Switch ON-OFF Pulse Set(0~59,59mm:ss), cycle set function(decimal) |
Current Setting / Max test time |
Bias & Test current –(setting of bias positive current /test positive current setting)/9999.9Hr |
Data reading & link number of machines |
read /record value of the voltage& temp. of channel and T/H values of each Chamber / max 32 Set |
Output & indicator |
1%±2mA & 0.1V/1mA |
Voltage / Current values Conversion curve |
record the voltage and Temperature values of each Channel can convert the Curve |
Voltage /Current/Temp. Analysis |
Recording of the start /sample/ end time of voltage/ temp. |
Excel report conversion |
Set condition data, measurement data and voltage shortage data converted as Excel file |
Power Source |
AC 220V/10A , 50/60Hz |
AC 220V/20A , 50/60Hz |