| odel |
MX-611H
|
| Measuring Gas |
Oxygen |
Carbon monoxide |
Flue gas temp. (optional) |
| Measuring Principle |
Galvanic cell |
Chronoamperometry |
Thermocouple |
| Sampling method |
Suction type Approx.0.6L/min (at room temperature with gas sampling probe) |
| Measuring Range |
0.0 - 25.0vol% |
0 - 5,000ppm |
0 - 750°C |
| Resolution |
0.1vol% |
1ppm |
1°C |
| Indication accuracy |
±0.5vol% |
0-200ppm;±20ppm of indication value
201-5,000ppm;±10% of indication value |
±5°C |
| Alarm accuracy |
±0.5vol% |
0-200ppm;±20ppm of indication value
201-5,000ppm;±10% of indication value |
±5°C |
| Display |
Digital liquid crystal |
| Alarm Method |
LED lamp, LCD display and buzzer |
| Response Time |
Within 15 seconds at 90% response |
Within 15 seconds at 90% response |
- |
| Power Supply |
3 x size AA Alkaline dry battery(LR6) |
| Continuous Operating time |
Approx. 20 hours, no alarm |
| Operating Temperature Range |
-10-40°C; 30-85%RH (non-condensing) |
| Main body dimensions |
78(W) x 200(H) x 50(D)mm |
| Main body weight |
Approx. 550g (including batteries) |
| Standard accessories |
Gas sampling probe with NOx filter, dust filter, carrying case |