Thiết bị phân tích khí thải WOHLER A 550

Mã sản phẩm: |
Thương hiệu:
Giá gốc:

Giá khuyến mại: Liên hệ ( Đã có VAT )

Tiết kiệm: (0%)

Thiết bị phân tích khí thải WOHLER A 550

Thông tin sản phẩm

Thiết bị phân tích khí thải WOHLER A 550


Technical Data
Oxygen concentration (O2) in flue gas
Display Volume % referenced to dry flue gas
Measurement principle Electrochemical sensor
Range 0.0-21.0 vol. %
Accuracy ± 0.3 Vol.-%
Carbon monoxide (CO 4,000 ppm) in flue gas (Wohler A 550)
Display Volume ppm referenced to dry flue gas
Measurement principle Electrochemical sensor
Range 0-4,000 vol. ppm; resolution 1 vol. ppm
Accuracy ±20 ppm (< 400 ppm), otherwise 5% of reading
Carbon monoxide (COhigh) in flue gas (optional)
Display Volume ppm referenced to dry flue gas
Measurement principle Electrochemical sensorr
Range 0-100,000 vol. ppm; resolution 1 vol. ppm
Accuracy ± 100 ppm (< 1,000 ppm), otherwise 10% of reading (with H2 < 5 % of reading)
Nitric oxide concentration (NO) in flue gas (optional)
Display Volume ppm referenced to dry flue gas
Measurement principle Electrochemical Sensor
Range 0-3,000 vol. ppm (continuously up to 1,000);
Resolution 1 vol. ppm
Accuracy ±5 Vol.-ppm (<100 ppm), otherwise 5 % of reading
Nitrogen dioxide concentration (NO2) in flue gas (optional)
Display Volume ppm referenced to dry flue gas
Measurement principle Electrochemical sensor
Range 0-1000 vol. ppm (continuously up to 200); resolution 1 vol. ppm
Accuracy ±5 vol. ppm (< 100 ppm), otherwise 5 % of reading
Sulfur dioxide (SO2) in flue gas (optional)
Display Volume ppm referenced to dry flue gas
Measurement principle Electrochemical sensor
Range 0-5,000 vol. ppm; resolution 1 vol. ppm
Accuracy ± 10 vol. ppm (0...200 ppm), otherwise 5 % of reading
Chimney draft / differential pressure (PD) with 4 Pa test (Wohler A 550)
Display inWC
Measurement principle Semi-conductor diaphragm
Range 0.00 to ± 44.16 inWC; resolution 0.004 inWC (< 4.01 inWC), otherwise 0.004 inWC, with ventilation loss measurement 0.004 inWC
Accuracy 0.0012 inWC (< 0.04 inWC), otherwise 3 % of reading
Drift < 0.00081 inWC in 5 minutes
Flue gas temperature (TS)
Display °F
Measurement principle Thermocouple (NiCr-Ni) (NiCr-Ni)
Range -4 °F to 1,472 °F; resolution 32.18 °F
Accuracy 32-271.4 °F: ± 35.6°F 271.4-1,472 °F: ± 1.5 % of reading
Combustion air temperature (TA)
Display °F
Measurement principle Thermocouple (NiCr-Ni)
Range -4 °F to 212 °F; resolution 32.2 °F
Accuracy ±33.8°F
Wood moisture
Display Mass of water referenced to dry fuel mass
Measurement principle Electrical resistance measurement
Range 10.0-40.0%; resolution 0.1%
Accuracy ±40% of reading tested to VDI 4206 Part 4
Power supply Lithium-Ion, rechargeable battery 3.7 V, 5800 mAh, charges via USB
Battery operating time Approx. 12 h (depends on operating status and display illumination)
Storage temperature -4 °F to +122 °F
Operating temperature +41-104 °F to maintain stated accuracy
Weight 2.75 lbs
Dimensions 8.7" x 6.3" x 2.2" (without probe)
Length of cable-hose 67"


SẢN PHẨM CÙNG DANH MỤC
@ 2016 NAB
buca escort
süperbetinbelugabahis giriş adresibetist girişvevobahisonwin girişjasminbetbetpasbetsatbetsmove girişmavibet
tipobet365 destekkralbetmarsbahissahabetmatadorbet
betmatik
free spin veren siteler
bahis.com girismeritroyalbetbetturkeyngsbahisarzbetkolaybetbetboopulibetnxpoker.com
hoşgeldin bonusu veren sitelerkazandıran slot oyunlarıbetistjasminbetnxpoker.comvevobahis
googleFaceBook twitter pokerklasen iyi bahis siteleristeemitcasino.combetmatik
arzbet girisyouwin girisiddaa tahminleriklasbahisbetmatikslot oynatipobetyouwin
süpertotobetonwintipobet365slot oyunları50 tl deneme bonusu veren siteler
oleybet destek sitesibetist girişsüpertotobetjasminbetngsbahis girişbahis ve casino siteleribetperanadolu casinobahis siteleribonus veren siteler