Safety standard |
IEC 61010-1, IEC 61010-2-032
Installation CategoryⅡ600V or CategoryⅢ300V. |
E.M.C. standard |
EN 61326 |
Measuring method |
Dual slope integration mode |
Range |
AC 0~30mA/300mA, 30A/300A, 2 range manual |
Accuracy |
23℃±5℃ 80%RH or less (50/60Hz)
Range
AC 30/300mA/0.01mA/±1.2% rdg ± 5dgt
AC 30/300A/0.01A/0~200A : ±1.2% rdg ± 5dgt 200~250A : ±3.0% rdg ± 5dgt 250~300A : ±5.0% rdg ± 5dgt |
Jaw opening capability |
40mmφ |
Display |
3.5 digit LCD, max. reading of 3200 |
Over range indication |
"OL" mark on LCD |
Data hold indication |
"DH" mark on LCD |
Low battery indication |
"Battery" mark on LCD |
Operating Temperature |
0℃ to 40℃, 80%RH max. ( Without condensation ) |
Storage Temperature |
-10℃ to 60℃, 70%RH max. ( Without condensation ) |
Auto power off |
Approx. 10 minutes later after power on |
Power supply |
1.55V (SR-44, LR-44)×2 |
Battery life |
Approx. 50 hours(LR-44) |
Power consumption |
5mW |
Withstanding Voltage |
AC 3700V 1 minute max. (Between the core of CT and outer case) |
Size |
64(W)×162(H)×23(D)mm |
Weight |
Approx. 125g |
Sampling |
2 times/sec (Digital display)
12 times/sec (Bar graph display) |
Accessories |
Soft case:1
Instruction manual:1
Batteries LR-44(1.55V):2
|