Withstanding Voltage |
AC 5500V 1 minute max. (Between the core of CT and outer case) |
Storage Temperature |
-10℃ to 60℃, 70%RH max. ( Without condensation ) |
Accuracy |
(23℃±5℃, 80%RH or less)
Function/Range/Resolution/Accuracy/Max. input
ACA(50/60Hz) DCA Manual range/40A/0.01A/±2%rdg±8 dgt/AC/DC2000A
ACA(50/60Hz) DCA Manual range/400A/0.1A/±1.5%rdg±8 dgt/AC/DC2000A
ACA(50/60Hz) DCA Manual range/2000A/1A/±1.5%rdg±8 dgt/AC/DC2000A
ACV(50/60Hz) DC V Auto/Manual range/400mV/0.1mV/±1.2%rdg±8 dgt/AC/DC 600Vrms
ACV(50/60Hz) DC V Auto/Manual range/4V/0.001V/±1.2%rdg±8 dgt/AC/DC 600Vrms
ACV(50/60Hz) DC V Auto/Manual range/40V/0.01V/±1.2%rdg±8 dgt/AC/DC 600Vrms
ACV(50/60Hz) DC V Auto/Manual range/400V/0.1V/±1.2%rdg±8 dgt/AC/DC 600Vrms
ACV(50/60Hz) DC V Auto/Manual range/600V/1V/±1.2%rdg±8 dgt/AC/DC 600Vrms
Frequency(Hz)/100Hz/0.01Hz/±0.5%rdg±3 dgt/AC/DC 600Vrms
Auto range/1000Hz/0.1Hz/±0.5%rdg±3 dgt/AC/DC 600Vrms
Auto range/10kHz/0.001kHz/±0.5%rdg±3 dgt/AC/DC 600Vrms
Auto range/100kHz/0.01kHz/±0.5%rdg±3 dgt/AC/DC 600Vrms
Auto range/1000kHz/0.1kHz/±0.5%rdg±3 dgt/AC/DC 600Vrms
Resistance(Ω) Auto/Manual range/400Ω/0.1Ω/±1.5%rdg±8 dgt/250 Vrms
Resistance(Ω) Auto/Manual range/4kΩ/0.001kΩ/±1.5%rdg±8 dgt/250 Vrms
Resistance(Ω) Auto/Manual range/40kΩ/0.01kΩ/±1.5%rdg±8 dgt/250 Vrms
Resistance(Ω) Auto/Manual range/400kΩ/0.1kΩ/±1.5%rdg±8 dgt/250 Vrms
Resistance(Ω) Auto/Manual range/4000kΩ/1kΩ/±1.5%rdg±8 dgt/250 Vrms
Continuity check/400Ω/0.01Ω/Approx. < 40Ω/250Vrms
Diode test/3V/0.001V/±10%rdg±3 dgt/250Vrms |
Operating Temperature |
0℃ to 40℃, 80%RH max. ( Without condensation ) |
Power supply |
1.5V (AM-4, LR03 or AAA)×2 |
Power consumption |
14mW |
Weight |
Approx. 350g |
AC Conversion |
Average sensing rms reading |
Safety standard |
IEC 61010-1, IEC 61010-2-032
Installation CategoryⅢ600V phase to earth. |
Jaw opening capability |
55mmφ |
Accessories |
Hard carrying case:1
Instruction manual:1
Test lead:1set
Batteries:2 |
Display |
3.5 digit LCD, max. reading of 3999 |
Over range indication |
Blanking of all digits except MSD 1 |
Data hold indication |
"DH" mark on LCD |
Low battery indication |
"Battery" mark on LCD |
Auto power off |
Approx. 10 minutes later after power on |
E.M.C. standard |
EN 61326 |
Measuring method |
Dual slope integration mode |
Battery life |
85(W)×240(H)×34(D)mm |
Sampling |
2 times/sec
|