Withstanding Voltage |
AC 3700V 1 minute max. (Between the core of CT and outer case) |
Storage Temperature |
-10℃ ~ 60℃ < 70%RH( without condensation ) |
Accuracy |
(23℃±5℃, 80%RH or less)
Range/Resolution/Accuracy
AC 40A/0.01A/±1.5%rdg±5dgt(50/60Hz)
AC 400A/0.1A/±1.5%rdg±8dgt(50/60Hz)
DC 40A/0.01A/±1.5%rdg±3dgt
DC 400A/0.1A/±1.5%rdg±5dgt
AC 60V/600V/0.01V/±1.0%rdg±8dgt
DC 60V/600V/0.01V/±1.0%rdg±6dgt
1000Ω/0.1Ω/±1.5%rdg±8dgt |
Operating Temperature |
0℃ ~ 40℃ < 80%RH ( without condensation ) |
Power supply |
1.5V (AM-4, LR03 or AAA)×3 |
Power consumption |
Approx. 9mA |
Weight |
Approx. 135g |
Measuring Range |
AC Current:40A/400A
DC Current:40A/400A
AC Voltage:60V/600V
DC Voltage:60V/600V
Resistance:1000Ω |
AC Conversion |
True rms responding |
Safety standard |
IEC61010-1, IEC61010-2-032
Installation CategoryⅡ 600V or CAT Ⅲ 300V |
Jaw opening capability |
30mmφ |
Limitation of circuit voltage |
Less than AC/DC 600V |
Size |
45(W)×180(H)×24(D)mm |
Accessories |
Soft case:1
Instruction manual:1
Test lead:1
Batteries:2 |
Crest factor |
< 2.5 |
Display |
3.5 digit LCD max. reading of 3999 |
Over range indication |
"OL" mark on LCD |
Data hold indication |
"DH" mark on LCD |
Low battery indication |
"B" mark on LCD |
Auto power off |
Approx. 10 minutes later after power on |
E.M.C. standard |
EN 61326 |
Measuring method |
Dual slope integration mode |
Sampling time |
2 times/sec |
Battery life |
Approx. 90 hours continuous |
Polarity |
"-" sign for negative polarity |
DC current zero offset |
By push button switch
|