Safety standard |
IEC61010-1, IEC61010-2-032
Installation CategoryⅡ 300V |
Measuring method |
Dual slope integration mode |
AC Conversion |
True rms responding |
Jaw opening capability |
20mmφ |
Measuring Range |
AC/DC 0~200mA/2000mA/10A |
Display |
3.5digit LCD max. reading of 1999 |
Accuracy |
(23℃±5℃, 80%RH or less)
Range/Input range/Resolution/Accuracy
AC 200mA/0~1999mA/100μA/±1.0%rdg±5dgt (50/60Hz)
AC 2000mA/0~199.9mA/1mA/±1.0%rdg±5dgt (50/60Hz)
AC 10A/0~9.99mA/0.01A/±1.0%rdg±10dgt (50/60Hz)
DC 200mA/0~199.9mA/100μA/±1.0%rdg±3dgt
DC 2000mA/0~1999mA/1mA/±1.0%rdg±3dgt
DC 10A/0~9.99mA/0.01A/±1.0%rdg±10dgt
Error by hysteresis of hall effect :±3%rdg |
Over range indication |
"OL" mark on LCD |
Data hold indication |
"DH" mark on LCD |
Low battery indication |
"B" mark on LCD |
Min. memory function |
"Min" mark on LCD with min. value |
Max. memory function |
"Max" mark on LCD with max. value |
Polarity |
"-" sign for negative polarity |
DC current zero offset |
By push button switch |
Auto power off |
Approx. 10 minutes later after power on |
Sampling time |
1.6 times/sec |
Storage Temperature |
-10℃ ~ 60℃ < 75%RH ( without condensation ) |
Operating Temperature |
0℃ ~ 50℃ < 80%RH ( without condensation ) |
Power supply |
1.5V (AM-3, LR6 or AA)×2 |
Limitation of circuit voltage |
Less than AC/DC 300V |
Battery life |
Approx. 120 hours or more |
Withstanding Voltage |
AC 2300V 1 minute max. (Between the core of CT and outer case) |
Size |
76(W)×194(H)×30(D)mm |
Weight |
Approx. 340g |
Accessories |
Carrying case:1
Instruction manual:1
Batteries:2
|