Model |
Input/Output |
Features |
Product |
Strain Gauge Input Alarm Trip
Factory Configured
APD 1500 from $289
APD 1520 from $309
Open Datasheet
Download Datasheet
|
Specify
strain gauge mV/V rating, mV range,
excitation voltage
Factory configured
100 Ω to 10000 Ω strain gauge
5 mV to 2000 mV
1-10 VDC excitation
APD 1500 Single Alarm Trip
Dual SPDT contact sets
Standard: HI alarm, non-latching, normal acting
See data sheet for alarm options
APD 1520 Dual Alarm Trip
2 independent SPDT contact sets
Standard: HI/LO alarms,
non-latching, normal acting
See data sheet for alarm options
|
- User adjustable setpoint(s)
- User adjustable deadband(s)
- 8 Amp SPDT contacts
- Input LoopTracker LED
- Alarm status LEDs
- Alarm options: LO, HI/HI, LO/LO
- Optional reverse acting
- Optional latching alarms
- Push to test/reset
- Remote push to test/reset
- Full I/O/power isolation
- Removable plugs
- DIN rail mount without tools
- Universal power 85-265 VAC, 60-300 VDC
- D option for 9-30 VDC, 10-32 VAC power
|
APD 1500, APD 1520
|
Strain Gauge, Bridge, Pressure Sensor, Load Cell to DC Isolated Signal Conditioner
Factory Configured
API 4051 G I from $319
Open Datasheet
Download Datasheet
|
Specify input range
Factory configured
One 350 Ω stain gauge, load cell or bridge sensor
1 mV to 2000 mV
Specify excitation voltage
4 to 10 VDC
Specify output range
Factory configured
0-1 V to 0-10 V
±1 V to ±10 V
0-1 mA to 0-20 mA, 4-20 mA
|
- LoopTracker LEDs for input and output
- Full I/O/power isolation
- RepalcesAction AP 4051
- Internal bridge excitation source
- Output test button
- Uses API-011 11-pin socket
- 115 VAC powered
- A230 option for 230 VAC
- P option for 85-265 VAC, 60-300 VDC power
- D option for 9-30 VDC power
|
API 4051 GI
|
Strain Gauge, Bridge, Pressure Sensor, Load Cell to DC Isolated Signal Conditioner
Factory Configured
APD 4051 from $319
Open Datasheet
Download Datasheet
|
Specify input range
Factory Configured
One 350 Ω stain gauge, load cell or bridge sensor
1 mV to 2000 mV
Specify excitation voltage
Factory Configured
4 to 10 VDC, 30 mA max.
Specify output range
Factory Configured
0-1 V to 0-10 V
±1 V to ±10 V
0-1 mA to 0-20 mA, 4-20 mA
|
- I/O LoopTracker LEDs
- Full I/O/power isolation
- Internal bridge excitation source
- Drive one bridge
- Output test button
- DIN rail mount
- 22.5 mm wide
- Universal power 85-265 VAC, 60-300 VDC
- Option D for 9-30 VDC, 10-32 VAC power
|
APD 4051
|
Strain Gauge, Bridge, Load Cell to DC Signal Conditioner
Non-Isolated
Field Selectable Minuteman Setup
API 4058 G from $329
Open Datasheet
Download Datasheet
Email Datasheet Link
|
Field configurable Input
0-5 mVDC to 0-1200 mVDC
Field settable excitation voltage
0-10 VDC in 1 VDC steps, 115 mA max.
18 Field configurable outputs
0-1 V to ±10 V
0-2 mA to 0-20 mA, 4-20 mA
|
- Minuteman one-minute setup
- I/O LoopTracker LEDs
- Internal bridge excitation source
- Drive one bridge
- Output test button
- Uses API-011 11-pin socket
- 115 VAC powered
- A230 option for 230 VAC
- P option for 85-265 VAC, 60-300 VDC power
- D option for 9-30 VDC power
|
API 4058 G |