|
Power supply voltage to sensor |
Load Cell DC12 V±1.2 V / within 40 mA/unit
Angle detector DC12 V±1.2 V / within 20 mA |
Input range |
Load cell F.S. setting can be made at the input from 0.5 mV/V to 3 mV/V
Angle detector 1.4 V ~ 5.6 V (-15° ~ 105°) |
Display of moment ratio |
Display range from 60 % to 125 % (Bar graph LED)
Minimum resolution 2.5 % |
Present load display |
Display range from -99 t to 999 t or from -9.9 t to 199.9 t |
Present working radius |
Display range from 0.0 m to 99.9 m |
Condition display |
Applied load cell is specified. (Load cell No.1 ~ 3) |
Monitor display |
One of the selection has been displayed either of Limit load, Limit radius, Jib angle, Moment No., Jib No. or Range No. |
Limited output monitor display |
Display output condition of limited output No.1 to No.6 |
Display of 90 % and 100 % |
Display signal output condition of 90 % and 100 % of the lifting load |
Display of up and down |
Display input signal condtion for correction executing instruction of lift-up and lift-down |
Display times |
Changeable to 1 times/s, 2 times/s or 0.5 times/s |
Buzer for emergency |
Parts No. EB2112 DC12 V, 35 mA |
Power supply voltage |
DC24 V (DC18 V ~ 36 V), Power consumption Approx. 3 A |
Outline dimensions |
100 mm(W) x 210 mm(H) x 162.9 mm(D)
(Excluding protruding parts) |
Weight |
Approx. 2.5 kg |
Angle detector Specifications |
|
Rated voltage |
DC10.5 V ~ 30 V |
Detecting angle |
-15° ~ 105° |
Output voltage |
Sensitivity 35 mV±1.2 mV (per 1° ) |
Linearity |
±1 %F.S. |
Current output |
4 mA or less |
Power consumption |
10 mA or less |
Weight |
Approx. 2 kg (including cable) |
Cable |
Approx. 15 m (Cable end is cut)
|