Analog inputs |
Six four-arm strain gage bridge inputs |
Bridge excitation |
Channel independent, software configurable – 2.5, 5 or 10 VDC |
Amplifier gains |
Channel independent, software configurable – 500, 1000, 2000, 4000 |
Auto zero |
Push button or software initiated |
Anti-aliasing filter |
1000 Hz low pass, 2-pole Butterworth |
Analog output range |
+/- 5 volts |
Analog output reconstruction filter |
1000 Hz low pass, 3-pole Butterworth |
Analog output DAC |
16 bit |
Sample rate |
Max: 1200 Hz/channel
Min: 10 Hz/channel |
Synchronization |
Genlock, external trigger, internal clock |
Digital Signal Processor |
16 bit |
Digital data |
IEEE 754 floating point, 32 bit |
Digital resolution |
14 ENOB |
Power supply
|
External medical grade (included) |
Connectors |
- Digital output: USB 2.0
- Sync/genlock: RCA phono
- Power: 5.5 mm x 2.1 mm plug |
- Analog output: DB25S
- Transducer Input: 26-pin circular type connector |