Model
|
PCR1000W
|
PCR2000W
|
PCR4000W
|
PCR8000W
|
PCR12000W
|
Rated input
|
Voltage
|
AC 85V~260V
|
Frequency
|
1Φ,50 Hz /60Hz
|
Power factor
|
0.94
|
Rated output AC mode
|
Voltage
|
1V~150V;2V~300V(150V/300VRange)
|
Maximum current
|
10A/5A
(150V/300VRange)
|
20A/10A
(150V/300VRange)
|
40A/20A(150V/300VRange)
|
80A/40A
(150V/300VRange)
|
120A/60A
(150V/300VRange)
|
phase
|
1
|
Power capacity
|
1000VA
|
2000VA
|
4000VA
|
8000VA
|
12000VA
|
Peak current
|
4 times than maximum current(RMS)
|
Frequency
|
1.0Hz~500.0Hz
|
Rated Output DC mode ,AC+DC mode
|
Voltage
|
1.4~212V/2.8~424V(150VRange/300VRange)
|
Maximum current
|
5.0A/2.5A(150V/300VRange)
|
10A/5A(150V/300VRange)
|
20A/10A(150V/300VRange)
|
40A/20A(150V/300VRange)
|
60A/30A(150V/300VRange)
|
Output Power
|
500VA
|
1000VA
|
2000VA
|
4000VA
|
6000VA
|
Voltage output stability
|
≤0.1%
|
Voltage output accuracy
|
≤1%setting+0.2V
|
frequency stability
|
≤0.03%Reading+0.1V
|
Efficiency of output frequency
|
≤0.016%setting+0.01Hz
|
THD
|
≤0.2%(40.0Hz~65.0Hz);≤0.3% (65.1Hz~500.0Hz)
|
Transient reaction time
|
<60μs
|
Load influence
|
≤0.2%+0.2V
|
Power voltage influence
|
≤0.1%
|
Power efficiency
|
≥75%
|
Measurement
|
Voltage
|
Range
|
75V/150V/300V
|
Resolution
|
0.1V
|
Basic accuracy
|
±(0.2%Reading+0.2%Range +1digit)
|
Current
|
Range
|
0.5A/1A/2A/5A/10A
|
1A/2A/5A/10A /20A
|
2A/5A/10A/20A/40A
|
5A/10A/20A/40A/80A
|
7A/15A/30A/60A/120A
|
Resolution
|
0.001A(0~9.999A);0.01A(10A~99.99A)
|
Basic accuracy
|
±(0.2%Reading+0.2%Range +1digit)
|
Power
|
Resolution
|
0.1W(0.1W~999.9W);1W(more than 1000W)
|
Basic accuracy
|
±(0.3%Reading+0.2%Range +1Digit)
|