Specifications
Pump |
Discharge Volume |
1.5〜2.5mℓ/stroke |
Discharge Pressure |
0.3MPa |
Motor |
Voltage / Current |
AC100Vφ1/50mA |
AC200Vφ1/25mA(50Hz) |
AC100Vφ1/42mA |
AC200Vφ1/18mA(60Hz) |
Output |
3W Synchronous Motor |
Emergency Detection |
Oil Level Switch |
Contact Type A Contact (NO) ON at low level |
Contact capacity 0.5A、AC
DC200V/30W smaller |
Operation Rating |
Continuous |
Working Viscosity Range |
32〜1300mm²/s |
Reservoir Capacity |
0.8ℓ |
Weight |
1.2kg |
Protection class |
IP54(CE Approved type) |
Directions for use
● Replace or clean the suction filter once a year.
Please see the adaptation table.
● Since oil changes its viscosity depending on the oil temperature in summer and winter, be careful to use it within the Working Viscosity Range. Please see the viscosity table.
● Do not use special additive oil, water-soluble oil or solvent.
● Regularly inspect the oil in use for contamination, etc. If any are found, immediately flush the tank and replace it with new oil.
● Please be careful about mistakes such as voltage.
● Do not overtighten the outlet fitting. Please refer to the tightening torque chart.
● Do not forcibly depress the oil level adjustment knob.
● Do not adjust the oil level when the oil level adjustment knob is raised. Please adjust at the lowest limit.