Measuring ranges 0…1 bar up to 0…400 bar
Linearity error including hysteresis <+ 0.2 % f.s.
Piezoresistive measuring system
Internal diaphragm (type series CB60 . .)
Flush mounted diaphragm (type series CE61 . .)
Wetted parts of stainless steel; completely welded
Stainless steel housing as standard or field housing
Degree of protection IP 65, IP 67 option
Output signal: 4…20 mA
Process temperature up to 140 °C (short term, for sterilization)
Options
Explosion protection for gases
Classification per SIL 2
Approval German Lloyd
Constructional design / case
 
Output
    
        
            | Signal: | 4…20 mA, 2-wire technology | 
        
            | Adjusting range: | approx. ± 5 % f.s., zero point and measuring span separately adjustable | 
        
            | Delay: | ≤ 20 ms | 
        
            | Current limitation: | ≤ 30 mA | 
        
            | Load, RB: | RB ≤ (UV-6V)/0.02A [KOhm] UV = supply voltage
 | 
        
            | Load influence: | for load change 500 Ohm: ≤ 0.1 % f.s.
 | 
    
 
 
 
 
    
        
            | Diaphragm: | Stainless steel mat.-no. 1.4404 (316L) | 
        
            | Socket: | Stainless steel mat.-no. 1.4404 (316L) | 
    
 
 
 
 
Measuring system
    
        
            | Sensor: | Piezoresistive | Thin film | 
        
            | Sensor filling: | Synthetic oil, free of silicone FD1, FDA listed | without | 
    
 
 
 
 
Supply voltage
    
        
            | standard design: |  | 
        
            | Nominal voltage: | 24 V DC | 
        
            | Functional range: | 6…30 V DC | 
        
            | max. allowable: | 30 V DC | 
        
            | Influence: | ≤ 0.01 % v.E. /V | 
    
 
 
 
 
    
        
            | Ambient: | -25…70 °C | 
        
            | Media: | -10...80 °C | 
        
            |  | with temperature decoupler (short term, for sterilization): -10...140 °C
 | 
        
            | Storage: | -40…90 °C | 
    
    
        
            | Lin./Hyst.: | < 0.2 % f.s. < 0.3 % f.s. for mr ≥ 0…60 bar
 Fixed point adjustment
 | 
        
            | Adjustment: | < ± 0.2 % f.s. | 
        
            | Temperature effect: | At 0…50 °C: Zero point ≤ 0.2 % / 10K
 Span ≤ 0.2 % / 10K
 | 
    
    
        
            | Sensor : | Piezoresistive | Thin film | 
        
            | Sensor diaphragm: | 1.4404/1.4435 (316L) | 1.4542 (630) | 
        
            | Socket: | 1.4404/1.4435 (316L) | 1.4301/1.4404 (304/316L) | 
    
    
        
            | Design: | See order details | 
    
    
        
            | Design: | - Field housing IP 65 or IP 67, with cable gland - Right-angle plug per EN 175301-803-A (DIN 43650, model A), IP 65
 - Cable connection IP 67
 - Circular connector M12, IP 65
 | 
        
            | Construction: | Electronics unit encapsulated with silicone | 
        
            | Material: | Stainless steel mat.-no. 1.4301 (304) | 
        
            | Pressure compensation: | Inner chamber aeration for measuring ranges < 16 bar over case thread or connection cable (depending on design) | 
        
            | Weights: | - Case with connector: approx. 200 g - field housing: + approx. 260 g
 - with temperature decoupler: + approx. 50 g
 |