| Case design: |
- fiel housing IP 65 or IP 67, with cable gland |
| |
- right-angle plug per EN 175301-803-A (DIN 43650 Form A), IP 65 |
| |
- cable connection, IP 67 |
| |
- circular connector M12, IP 65 |
| |
case material stainless steel union nut: polyamide (with plug connector or cable connection for electr. connection)electronics encapsulated with silicone. |
| |
Inner chamber aeration for measuring ranges < 16 bar over case thread or connection cable (depending on design) |
| Process connection: |
see next page or order code for variantsmaterial-Nr.: 1.4404 (316L) for the sleeves |
| Temperature ranges: |
ambient temperature range: -25...+70 °C
storage temperature range: -10...+90 °C
process temperature: see order details |
| Measuring ranges/overrange limits: |
see order details
intermediate measuring ranges upon request |
| Response time: |
≤ 20 ms |
| Measuring accuracy: |
see data sheet |
| Auxiliary energy supply: |
standard design:·
- nominal voltage 24 V DC
- function range 6...30 V DC
- max allowable operating voltage 30 V DC |
| Supply voltage influence: |
≤ 0,01 % v.E./V |
| Output signal: |
4...20 mA, 2-wire technology
0...20 mA, 3-wire technology
4...20 mA, 3-wire technology
0...10 V, 3-wire technology |
| Current limitation in output signal: |
max. output current approx. 30 mA |
| Adjusting range: |
approx. ± 5 % f.s., zero point and measuring span separately adjustable |
| Burden: |
standard design Ra= UB-6V / 20 mA (KOhm)
UB= operating voltage
Ra= max. permissible burden resistance (incl. lead) |
| Burden influenc: |
for 500 ohm burden change: ≤ 0,1 % v.E. |
| Functional safety: |
EN 61508, classificatio per SIL2, TÜV-Reg.-No.44 799 13190204 |
| Weights (without diaphragm seal): |
- field housing: ca. 460 g
- case with connector: ca. 200 g |
| Installation position: |
any |
| EMC test: |
- noise immunity according to EN 50082 section 2, version March 1995 issue for industry
- emitted interference according to EN 50081 section 1, 1993 issue for residential and industrial areas |