High-resolution graphic display with Intuitive 4-button operation and backlight
Comprehensive parameterising functions
Comprehensive simulation and diagnostic functions
Quick access to device data
Development according to SIL2
Nominal range 0,25 bar to 400 bar
Turndown up to 100:1
Measuring rate up to 100 Hz
Output signal 4…20 mA with HART® protocol
Configuration memory
Digital communication via PDM, FDT/DTM, 375/475 Field Communicator
Pressure transmitter with diaphragm seal technology for the measuring of relative and absolute pressures of gases, vapors and liquids
Stainless steel case in sturdy design, degree of protection IP 65/67
Accuracy 0.1 %
Output functions: linear, invers, square root, table function with up to 64 support points
Media temperature -40…400 °C
Case design process connection bottom
Case design process connection back
Various process connections
Approved according to NAMUR 95
EAC declaration (upon request)
Options
Explosion protection for gases and dust
Classification per SIL2
Certificate of measuring equipment for Russian Federation
Material certificate per EN 10204
Calibration certificate per EN 10204
Active temperature compensation (ATC technology) upon request
Removable display and control unit
Degree of protection IP 69K
Front cover of stainless steel with window of non splintering glass
Constructional design / case
Design: |
Two-chamber case, continuously rotatable by ± 170°
Case surface blasted |
Material case: |
- Stainless steel mat.no. 1.4301/1.4305 (304/303)
- Stainless steel mat.no. 1.4404 (316L) |
Material front cover: |
- Polypropylene, black
- Stainless steel mat.no. 1.4305 (303)
- Stainless steel mat.no. 1.4404 (316L) |
Gaskets: |
Silicone / NBR |
Degree of protection per EN 60529: |
- IP 65 / IP 67
- IP 69K |
Climatic category per EN 60721 3-4: |
4K4H |
Vibration resistance per EN 61298-3: |
10…60 Hz: ± 0.35 mm
60…1000 Hz: 5 g |
Material window: |
- Macrolon
- Non splintering glass (requires front cover of stainless steel) |
Elec. connection: |
- Circular connector M12
- Cable gland M16x1.5, PA black
- Cable gland M16x1.5, stainless steel
- Cable gland M20x1.5, PA black
- Cable gland M20x1.5, stainless steel
- 1/2" NPT, PA black |
|
Further connections upon request |
Terminal blocks: |
Spring clamp terminals up to 1.5 mm2
Pole terminals up to 2.5 mm2
Screwed terminals up to 2.5 mm2 |
Weight: |
approx. 1.4 kg (without diaphragm seal) |
Type plate: |
Laser marking |
Material wetted parts
Material: |
See order details |
Reference cond.: |
per DIN EN 60770-1 |
|
TU = const. (15…25) °C
φ = const. (45...75) % r.F.
pU = const. (860...1060) mbar
UB = 24 V DC (± 3 V DC)
RB = 50 Ω, HART: 250 Ω
Ground connected
MBA = 0 bar |
Calibration position: |
Vertical mounting position, bottom connection |
Deviation of characteristic: |
Refer to the adjusted measuring span (Limit point method per DIN 16086) |
|
Nominal range 1-400 bar, 1-16 bar abs.: |
|
Turndown 5:1 0.1 %
Turndown > 5:1 0.02 % x TD |
|
Nominal range 0.25 bar: |
|
Turndown 5:1 0.2 %
Turndown > 5:1 0.04 % x TD |
Long-term drift: |
Refer to nominal range ≤ 0.1 %/year |
Operational availability: |
< 12 s |
Response time t90 at current output: |
Refer to nominal range |
Temperature influence, case: |
Ambient temperature -20…80 C: |
|
Nominal range 1-400 bar
0.1 % /10K, max. 0.3 % |
|
Nominal range 0.25 bar
0.15 % /10K, max. 0.4 % |
|
Ambient temperature -40…-20 C: |
|
Typical 0.2 % /10K |
Design: |
See order details |
Up to a turndown of 100:1 the measuring span can be freely selected |
For detailed information see data sheet. |