| Pressure type |
Absolute pressure |
| Principle of Measurement |
Strain gauge |
| Rated Capacity |
5000,10000,15000bar |
| Initial Value |
0bar |
| Operating Range at Reference Temperature |
120% |
| Overload Limit at Reference Temperature |
120% |
| Test Pressure |
5000bar:200% 10000bar:130% 15000bar:100% |
| Destructive Range |
5000bar:>200% 10000bar:>130% 15000bar:>100% |
| Max. Dynamic Pressure (*1) |
5000bar:>100% 10000bar:>70% 15000bar:>55% |
| Destructive Range |
Permissible Vibration Amplitude (*1) |
5000bar:3500bar 10000bar:5000bar 15000bar:6000bar |
| Natural Frequency of the Membrane |
>100kHz |
| Dead Volume (Approximation) |
5000bar:615mm³ 10000bar:150mm³ 15000bar:100mm³ |
| |
for Included Packing (5000bar only) |
5000bar:200mm³ |
| Control Volume |
1mm³ |
| Material |
of the Parts In Contact with the Measurement Medium |
5000bar:1.4301,1.4542 10000,15000bar:1.4542 |
| of the Parts In Contact with Environment |
1.4542, 1.4301, Nickel plating brass |