- Small design (G1/8 thread)
- High accurate (Non Linearity: ±0.5%R.O.)
- Suitable for measurement of viscous media since the flush type (no feed port) wetted part is hardly clogged up.
- Wetted part constructed integral with diaphragm does not use any sealed liquid, offering durability, reliability and long life.
Rated Output(R.O.) |
Approx. 1mV/V |
Non Linearity |
0.5%R.O. |
Hysteresis |
0.5%R.O. |
Excitation;Recommended |
6V |
Excitation;Maximum |
10V |
Zero Balance |
±0.6mV/V |
Input Terminal Resistance |
100MΩ or more |
Output Terminal Resistance |
350±10Ω |
Insulation Resistance (*1) |
350±10Ω |
Compensated Temperature Range
(Temperature of medium to be measured) |
0~70°C(No condensation or freezing) |
Safe Temperature Range
(Temperature of medium to be measured) |
-5~80°C(No condensation or freezing) |
Safe Overload Rating |
150%R.O. |
Temperature Effect on Zero Balance |
±0.8%R.C./10°C |
Temperature Effect on Load |
±0.8%R.C./10°C |
Pressure Port Material |
SUS630 |
IP Rating |
Equivalent to IP65 |
Cable |
4.5-4-core shielded cable |
Weight |
50g(Cable not included) |
Accessories |