| Composition | 
            AISI 316L stainless steel integrated transmitter body | 
        
        
            | Power supply | 
            24 Vdc (10 ÷ 35 Vdc) current loop 4 ÷ 20 mA (2 wires) | 
        
        
            | External connections | 
            Standard: PVC shielded cable with nickel-plated brass cable gland | 
        
        
             | 
            Special: EFTE shielded and armoured cable, with AISI 316L steel cable gland | 
        
        
             | 
            Transmitter - 60°C ÷ + 120°C | 
        
        
             | 
            IP 68 (submersible depth 70 mt) | 
        
        
            | Environmental | 
            Standard cable: - 20°C ÷ + 80°C | 
        
        
             | 
            Special cable: - 60°C ÷ + 150°C - resistance UV | 
        
        
            | Measure type | 
            Omnidirectional seismic (absolute vibration) | 
        
        
            | Dynamic field | 
            ± 18 g | 
        
        
            | Transverse sensitivity | 
            < 5 % | 
        
        
            | Linearity | 
            ± 2% - 75 Hz | 
        
        
            | Dynamic performances | 
            ±3% / 10Hz-1kHz - see Figure 2 | 
        
        
             | 
            -3db / 1,5Hz - 2kHz | 
        
        
            | Insulation | 
            ≥10⁸ Ω between signal and case | 
        
        
            | Application axis | 
            Any | 
        
        
            | Standard machine connection thread | 
            M8x1,25 |