Cảm biến đo lưu lượng Ono Sokki FP-2140S, FP-215, FP-2250A, FP-4135
P-213 Small flow rate type
- Applicable fluids: gasoline, light oil, kerosene,
or standard petroleum oils
* Option: Alcohol fuels (methanol, ethanol, gasohol etc.)
- Measurement range: 0.06 to 60 L/h
- Wide range ability: 1:1000
- High accuracy, high pressure resistant design
- Capable of compensating for errors caused by pulsating or
backflow by means of a function for judging the direction of rotation.
- Small and light weight, ideal for on-board measurement
FP-213S Small flow rate, low pressure loss type
- Applicable fluids: gasoline, light oil or kerosene
Option: Alcohol fuels (methanol, ethanol, gasohol etc.)
* Please consult us when you use standard petroleum oils.
- Measurement range: 0.06 to 60 L/h
- Wide range ability: 1:1000
- Low pressure loss (10 Pa or less), ideal for measuring the amount of
· fuel consumption of motorcycles and heating equipments
- High accuracy, high pressure resistant design
- Capable of compensating for errors caused by pulsating or
backflow by means of a function for judging the direction of rotation.
- Small and light weight, ideal for on-board measurement
-
FP-2140H Standard flow rate type
- Applicable fluids: gasoline, light oil, kerosene or standard petroleum oils
* Option: Alcohol fuels (methanol, ethanol, gasohol etc.)
- Measurement range: 0.3 to 120 L/h
- High accuracy within±0.2% of reading, high pressure resistant design
- Wide range ability: 1:400
- Capable of compensating for errors caused by pulsating or backflow by means of a function for judging the direction of rotation
- Small and light weight, ideal for on-board measurement
-
FP-2240HA Standard flow rate/simultaneous measurement of temperature and pressure type
- Applicable fluids: gasoline, light oil, kerosene or standard petroleum oils
* Option: Alcohol fuels (methanol, ethanol, gasohol etc.)
- Measurement range: 0.3 to 120 L/h
- High accuracy within±0.2% of reading, high pressure resistant design
- Wide range ability: 1:400
- Simultaneous measurement of temperature and pressure
- Capable of compensating for errors caused by pulsating or backflow by means of a function for judging the direction of rotation.
- Small and light weight, ideal for on-board measurement
-
FP-2140S Low pressure loss & ultra wide range, High accuracy and high resolution
-
- Applicable fluids: gasoline, light oil, kerosene
* option: alcoholic fluids
(methanol, ethanol, mixture of alcohol and gasoline)
- Measurement range: 0.05 to 200 L/h
- Wide range ability of 1:4000 flow ratio
- Low pressure loss (10 Pa or less), available fuel consumption measurement such as general vehicles, two-wheels and heater
- Reading value accuracy of ±0.2%, resolution of 0.01 mL are achieved in all measurement range
- Rotational direction judgment function enables accurate flow measurement without influence from backward or pulsating flow.
- Suitable for on-board use
- CE marking
FP-215 Large flow rate type
- Applicable fluids: gasoline, light oil, kerosene or standard petroleum oils
* Option: Alcohol fuels (methanol, ethanol, gasohol etc.)
- Measurement range: 1 to 1440 L/h
- High accuracy within ±0.5% of reading, high pressure resistant design
- Wide range ability: 1:1440
- Capable of compensating for errors caused by pulsating or backflow by means of a function for judging the direction of rotation.
- Small and light weight, ideal for on-board measurement
- Ideal for measuring the flow rate of engines used in buses, trucks, and other large vehicles, as well as marine engines
FP-2250A Large flow rate/ simultaneous measurement of temperature and pressure type
- Applicable fluids: gasoline, light oil, kerosene or standard petroleum oils
* Option: Alcohol fuels (methanol, ethanol, gasohol etc.)
- Measurement range: 1 to 1440 L/h
- High accuracy within ±0.5% of reading, high pressure resistant design
- Wide rang ability: 1:1440
- Simultaneous measurement of temperature and pressure
- Capable of compensating for errors caused by pulsating or backflow by means of a function for judging the direction of rotation.
- Small and light weight, ideal for on-board measurement
- Ideal for measuring the flow rate of engines used in buses, trucks, and other large vehicles, as well as marine engines
FP-4135 On-Board Volumetric Flow Detector
- High precision
Measurement range: 0.1 to 200 L/h
Accuracy : ±0.2 %
Resolution : 0.01 mL
- Wide temperature range
Designed to support temperature variation in an engine room, and environmental test
Wide temperature range from -30 to 100 ℃
- Compact body
Built-in temperature sensor which is required for fuel consumption measurement and downsized filter enable 70% reduction in volume. (Compared to main unit of the FP-2140H of Ono Sokki, excluding signal processing part.)
- Supports wide variety of fuels
It can measure a variety of fuels including gasoline, alcohol, and light oil etc. as standard.
-
Provided pressure loss compensation function
-
No pressure device is required for the detector
-
Wide measurement flow area with one unit (from 0.05 to 200 L/h, FP-213S + FP-2140H )
|