Cảm biến đo PH, RX (ORP), độ dẫn điện, Clo dư FWT Systems
FWT offers PH and RX (ORP) electrodes in two types:
PH AND RX (ORP) ELECTRODES PLASTIC BODY WITH CABLE
EPH range pH 0...14, Single bulb junction
ERX range ± 2000 mV, Platinum disc single junction
6 bar (100 psi) / 0....60°C
plastic shaft Polycarbonate, maintenance free gel electrolyte
connector head with fixed coaxial cable D/3 mm (length 1m or 5 m) + BNC
suitable for most pH and RX (ORP) controllers
Applications: laboratory, swimming pools, water treatment, process industry
Each electrode is provided with a Storage Solution bottle.
Recommended to place the electrode for storage when it’s not in use.
PH AND RX (ORP) ELECTRODES WITHOUT CABLE AND HIGH PERFORMANCES
EDINPHG range pH 2..14 (0..14 short period) / 0...60 °C / 0…6 bar
EDINRXG (ORP) range -1000 ... + 1000 mV / 0...60 °C / 0…6 bar
EDINPHG10 range pH 0..14 / 0..80 °C (briefly 100°C) / 0..10 bar, Ceramic porous setting, Min.EC 100 μS/cm sample
glass shaft, single pore, maintenance free gel
connector type S8– standard connector head with integrated PG13,5 thread
suitable for most pH and RX (ORP) controllers
Applications: electroplating, swimming pools, water treatment, waste water, chemical, oxides
EPHG130 range pH 0...14 / Min.EC 50 μS/cm sample
Maintenance free electrode designed for high pH values applications, high temperature and pressure
0....130 °C / 0….16 bar at 25°C / 0….6 bar at 130°C
ATEX approval CE 0035 EX II 1/2 G EEx ia IIB T4/T5/T6
glass shaft, single pore, maintenance free gel
connector type S8– standard connector head with integrated PG13,5 thread
suitable for most pH and RX (ORP) controllers
Applications: chemical industry, oxides, water and waste water
EPH6POL range pH 0... 14 / Min.EC 50 μS/cm sample
Maintenance free electrode designed for all water applications
-10....40 °C (briefly 60°C) / 0….6 bar
ATEX approval CE 0035 EX II 1/2 G EEx ia IIB T4/T5/T6
plastic shaft, single pore, maintenance free gel
connector type S8– standard connector head with integrated PG13,5 thread
Applications: water and waste water, Swimming pools, fish farming
EPHFL range pH 0... 14 / Min.EC 5 μS/cm sample
Maintenance free electrode designed for all water applications
-5....100 °C / 0….6 bar
ATEX approval CE 0035 EX II 1/2 G EEx ia IIB T4/T5/T6
glass shaft, single pore two diaphragms
connector type S7 – standard head with integrated PG13,5 thread
Applications: presence of high levels of hydrofluoric acid
EPHALK range pH 0... 14
Maintenance free electrode designed for all water applications
-5....100 °C / 0….6 bar
ATEX approval CE 0035 EX II 1/2 G EEx ia IIB T4/T5/T6
glass shaft, single pore two diaphragms
connector type S7 – standard head with integrated PG13,5 thread
Applications: presence of high levels of alkaline substances
CHLORINE MEASUREMENTS
Two types of chlorine measurement sensors are available:
- ion selective potentiostatic membrane sensors
- open system amperometric chlorine cell
ION SELECTIVE MEMBRANE CHLORINE SENSORS
CC1Hun Free Inorganic-Organic chlorine
Range: 0.005 ….. 2 ppm (mg/l) free chlorine
Resolution: 0.001 ppm (mg/l)
Signal (nominal slope): -1000 mV/ppm pH-compensated
Power supply: ±5 to ±12,5 Vdc / 10 – 25 Vdc 25mA
Operating temperature: > 5 … < 45°C, automatic compensation by integrated temperature sensor
pH range: pH 4 - pH 12 (low pH dependency)
Flow requirement: approximately 30 l/h
Pressure: 0,5 bar, no sudden pressure surges, impulses and/or vibrations or fluctuations
Suitable chlorinating agents: NaOCl (sodium hypochlorite); Ca (OCl)2 (calcium hypochlorite); chlorine gas;
Compatibility: Tensides: Isocyanuratic / Surfactants / Flocculants
Application 1 standard duty (CLS2-CLS20) water treatment (also drinking water), swimming pool
Application 2 with Gel ECC1S (upon request) sea water
CC1N Free Inorganic-Organic chlorine
Range: 0.05 ….. 20 ppm (mg/l) free chlorine
Resolution: 0.01 ppm (mg/l)
Signal (nominal slope): -100 mV/ppm pH-compensated
Power supply: ±5 to ±15 Vdc / 10mA
CLST2.1Hun Total chlorine
CLST20.1N Total chlorine
Application 1 standard CLST2.1Hun water treatment (also drinking water),swimming pools
(NOT compatible with surfactantsfats/oil)
Application 2 with electrolyte ECP2S/GEL sea water (tensides are partly tolerated)
AS2N Inorganic Free chlorine
Measuring method: open probe amperometric 3 electrode system (NOT galvanic isolation)
Flow rate / Pressure: 80 l/h / AS2 5 bar; AS3 approximately 8 bar
Application AS2 drinking water, services for cold and hot water up to max 70°C, high pressure)
Application AS3 drinking water, swim. pools, closed systems cold / hot water: legionella control
AS3H / AS3N-CL Inorganic Free chlorine
OPEN SYSTEM AMPEROMETRIC CHLORINE CELLS
Open system amperometric cell able to the measure organic and inorganic free chlorine with 0-10 mg/lt reading (ppm), with regulation of the in-coming water flow, suitable to host temperature probe and proximity switch.
CLC3 amperometric cell with 2 electrodes holders and proximity switch, capable to host temperature probe
CLC2 amperometric cell with 2 electrodes holders, capable to host proximity switch and temperature probe
CLC4 amperometric cell capable to host proximity switch and temperature probe
PMMA body with PP electrode holders
Self-cleaning cell with glass balls
Range 0?10 ppm. Electrode Platinum/Copper in vertical position to avoid bubbles
Flow adjustment: 40?50 l/h or by visual adjustment (to be steady and continuous)
2 electrodes holder, Proximity switch and temperature probe
Max pressure 5 bar - Max temperature 5?60°C
CONDUCTIVITY EC MEASUREMENTS
SCD Conductivity sensors, two electrodes open systems, provided with cable.
Suitable for many basic applications at a short distance (max 8 / 9 m).
Ranges K1 20.000?S / K5 200 - 2.000Ms
Probes electrodes: Graphite or AISI316
Probes body: PTFE or PVC
Remarks: Graphite electrodes have more accuracy at high conductivity ranges (K1 can reach 100 mS range)
Available upon request High resolution EC sensors with stem type shaft
PPM MEASUREMENT SENSORS
The following are sensors for various applications, which have in common the measurements range in ppm.
For ppm measurements FWT has TOUCH and CTRL+ series controllers.
CN1-H-A12n / CN1N-A12n Absence of chlorine
Application: to verify the absence of chlorine in water for drinking quality (e. g. reverse osmosis)
CLS CD4H / CLS CD4N / CD7H / CD7N / CD7L Chlorine-dioxide
Application: Swimming-pool, drinking water, process water; It must NOT contain tensides all types of water
treatment, bottle washer, CIP plant; Tensides are tolerated
MST1N measurement of chlorite
Application: measurement of chlorite for drinking water, swimming pool, process water
WP7Hun / WP7Un / WP10 L-A12n / WP10-20%A12n Hydrogen Peroxide
Application: All types of water treatment (e. g. bottle washer, CIP plant, rinser) for high H2O2 concentration
WP10 L-A12n / WP10-20%A12n Hydrogen Peroxide
Application: All types of water treatment especially for high H2O2 concentration
OZ1H / OZ1HN / OZ7H / OZ7HN dissolved ozone
Application: all types of water treatment (CIP plants,rinser); swimming pools, drinking water, process water
BR1-N / BR1N-A12n Bromine measurement
Application: measure of Hypobromous acid HOBr for Drinking water; swimming-pool; process water
PES7H / PES7N / PES7L peracetic acid
Application: all water treatment, conductivity acids are tolerated, Tensides must NOT to be present
SENSOXY dissolved oxygen sensor with cable
Application: Water treatment, Waste water treatment, swimming pools, fish farms; composting facilities
OTHER SENSORS
PROXIMITY SWITCH SPROX
Inductive proximity switch to detect in-coming flow, suitable for OFF-Line sensor holders “Base module” and
chlorine cell model CLC3-CLC4
TEMPERATURE SENSOR STEMP-N
Temperature sensor PT100 “cap” type, suitable for OFF-Line sensor holders “Base module” and chlorine cell
model CLC3. Material PVC 1/2” thread, Tmax 45°C, Max pressure 5 bar, provided with 5 m cable
TEMPERATURE SENSOR PT100
suitable for OFF-Line sensor holders.
SPT100 G Temperature sensor, GLASS PYREX body, Tmax 100°C, Max pressure 2 bar, provided with 5 m cable
SPT100 A Temperature sensor, AISI 316 body, Tmax 200°C, Max pressure 2 bar, provided with 5 m cable