| Detection method | An internal hall element and electromagnetic property gear | 
        
            | Detective gear | Strong magnetic properties (e.g., S20C, SS400 etc.) involute type Module: 0.5 to 3, Tooth width: 3mm or more
 | 
        
            | Detection distance | Depends on gear module | 
        
            | Measurement range | 1 Hz to 100 kHz (1 to 100,000r/min at 60P/R detective gear)* | 
        
            | Output method | Voltage output (collector output method) | 
        
            | Output signal | Rectangular waveform Hi level:+5 ± 0.5 V or less,  Lo  level:+ 0.5 V or less | 
        
            | Output impedance | Approx. 330 Ω | 
        
            | Applicable tachometers | TM-3100 series, TM-5100 etc. | 
        
            | Applicable F/V converters | FV-1500, FV-1400**, FV-5300** | 
        
            | Power requirement | 12±2 VDC, approx. 40 mA | 
        
            | Protection circuit | Power supply polarity protection | 
        
            | Operating temperature range | -10 °C to +70 °C | 
        
            | Storage temperature range | -20 °C to +80 °C | 
        
            | Operating humidity range | 20 to 80 % RH(with no condensation) | 
        
            | Storage humidity range | 20 to 80 % RH(with no condensation) | 
        
            | Withstand voltage | 250 VDC | 
        
            | Resistance to vibration | At 49 m/s2 in X, Y and Z for each direction. (during operation) | 
        
            | Resistance to shock | 490 m/s2 in X, Y and Z direction each three times. (Non-operating) | 
        
            | Outer dimensions | 75 (W) × maximum diameter 24 mm | 
        
            | Weight | Approx. 80 g (including mounting nuts) | 
        
            | Signal cable | Sold separately (30 m or less, MX-7100 / 8100 series connection cables in used) |