| Display (LCD, Digital Counts) | 1999 | 
        
            | AC Current Accuracy (200A Reference) | 1.5+4(50/60Hz) 2.0+5(40~1kHz)
 | 
        
            | AC Current Accuracy (600A Reference) | 1.5+4(50/60Hz) 2.0+5(40~1kHz)
 | 
        
            | AC Voltage Accuracy (200V/600V Reference) | 1.0+2(50/60Hz) 1.5+4(40~1kHz)
 | 
        
            | Crest Factor | (50/60Hz) | 
        
            | Resistance Accuracy (200Ω reference) | 1.2+4, Beeps at below 30Ω (continuity check) | 
        
            | Method of detection | True RMS | 
        
            | Response Time | Approx. 1 seconds (approx. 2 seconds on resistance range) | 
        
            | Range Switching | Manual-range | 
        
            | Data hold | On all range | 
        
            | Operating temperature and humidity | -10-50°C. (no condensation) up to 30°C, 90% RH
 up to 40°C, 75% RH
 up to 50°C, 45% RH
 | 
        
            | Influence of external magnetic field | 2A or less at 400A/m | 
        
            | Influence of conductor position | ± 3% or less | 
        
            | Safety Standard | Conforms EN 61010-1, EN61010-2-031, EN61010-2-032 | 
        
            | Circuit voltage | 600Vrms or less | 
        
            | Withstanding voltage | 5.55kV AC for one minute | 
        
            | Power Supply | 6F22(006P)9Vx1 or 6LR61x2 | 
        
            | Battery Life1 | 100 hours | 
        
            | Consumed current | Approx. 2mA | 
        
            | Auto power-off | Approx. 10 minutes | 
        
            | Diameter of measurable conductor | 30mm at maximum | 
        
            | Dimensions | Approx. 93(W)x210(H)x40(D)mm | 
        
            | Weight (Approx.) | 400g | 
        
            | Accessories | Clamp Adapter (Model 99025), Carrying Case (Model 93032), Test Lead (Model 98010), User's manual (IM CL120), batteries | 
        
            | Order Notes | Each item selected MUST be ordered as a separate line item. | 
        
            | Product Notes | All Clamp-on Meters include Test Leads (where applicable) and a carrying case. |