| Specifications of Digital Counters | 
        
            | Model | C-500 | C-700 | 
        
            | 
                
                    
                        |  Displayed digits |  
                        |  |  Selection of 10µm |  
                        |  |  Selection of 1µm |  
                        |  Display |  | 
                
                    
                        | -9999.99 -- 00.00 -- 9999.99 |  
                        | -999.999 -- 0.000 -- 999.999 |  
                        | High-luminance LED display with 7 segments (red) |  | 
        
            | 
                
                    
                        |  Power supply voltage & power consumption
 |  | AC100V -- AC240V / 9VA or lower
 | 
        
            | 
                
                    
                        |  Operating temperature |  | 0 -- +40ºC | 
        
            | 
                
                    
                        |  Compatible Linear Gauges |  
                        |  |  Selection of 10µm display |  
                        |  |  Selection of 1µm display |  | 
                
                    
                        | DL-2, D-5, D-10, D-20, D-30, D-50, D-100, DN-10, DN-20, D-5UZ |  
                        | DL-2S, D-5S, D-10S, D-20S, D-30S, D-50S, D-100S DN-10S, DN-20S |  | 
        
            | 
                
                    
                        |  Accessories |  | 
                
                    
                        |  AC power cord (2m) ; One cord |  
                        |  Metal fittings for panel installation ; Two units |  
                        |  | ( to be used for installation in panel and securing stand fittings ) |  
                        |  Stand fittings ; One unit |  
                        |  | ( to be used when counter is used as desktop device ) |  | 
        
            | 
                
                    
                        |  Terminal block functions ( Rear panel )
 |  | 
                
                    
                        |  Terminal block | --> Screwless terminal block |  
                        |  Usable electric cables | --> AWG22 - 28 |  
                        |  Length of peeled wire of cables | --> 8 - 9mm |  
                
                    
                        |  Pin alignment |  
                        | (*1) | St/Sp | Controls "START" and "STOP" of MAX, MIN, P-P measurement mode.
 |  
                        | (*2) | React | Controls "SUSPEND" and "START" of P-P measurement mode.
 |  
                        | 3 | Latch | Controls "LATCH" and "CANCEL" of measured value. |  
                        | 4 | Reset | External "RESET" "PRESET" ( Function available only in Model No. C-700 )
 |  
                        | 5 | Alarm | Error signal output |  
                        |  | Max Display
 | Min Display
 | P-P Display
 |  
                        | (*6) | -NG | Outputs -NG based on OK±NG judgment (red LED).
 | --> | +NG(2) | -NG(1) | NG(2) |  
                        | (*7) | OK | Outputs OK based on OK±NG judgment (green LED).
 | --> | OK | OK | OK |  
                        | (*8) | +NG | Outputs +NG based on OK±NG judgment (orange LED).
 | --> | +NG(1) | -NG(2) | NG(1) |  
                        |  | (1) : NG output in first stage (2) : NG output in second stage
 |  
                        | 9 | GND | GND |  
                        | (* ) | Circled numbers indicate functions available only in Model No. C-700 |  | 
        
            | 
                
                    
                        |  Dip sw setting functions ( Printed circuit board )
 |  | 
                
                    
                        | Dip(1) |  | Dip(2) |  
                        | SW 1 | Select 1µm or 10µm |  | SW 1 | Settings by Manufacturer |  
                        | SW 2 | Select direction of counting.
 |  | SW 2 | Select whether or not to include default values for OK±NG judgment.
 |  
                        | SW 3 | Select activation or non- activation of error output.
 |  | SW 3 | Select either "orthogonal" or "sine" for input waveform.
 |  
                        | SW 4 | Select activation or non- activation of overflow.
 |  | SW 4 | Select either 400msec or 100msec for RESET time.
 |  | 
        
            | 
                
                    
                        |  Data output (RS-232C) D-Sub9P plug
 INCH screw
 |  
                        |  |  
                
                    
                        |  Options |  
                        |  |  Excel input software |  
                        |  |  BCD output board |  | 
                
                    
                        |  Pin Alignment |  
                        | 1 | NC | -- |  |  Communication mode ; Half-duplexasynchronouscommunication |  
                        | 2 | Rxd | in <-- |  |  Communication speed ; 9600bps |  
                        | 3 | Txd | --> out |  |  Format ; 7Bit ASCI I |  
                        | 4 | NC | -- |  |  Parity ; even number |  
                        | 5 | SG | -- |  |  Stop bit ; 1Bit |  
                        | 6 | NC | -- |  |  RTS / CTS ; Returned when not in use. |  
                        | 7 | RTS | --> out |  |  Reception command ; Transmission request ASCI I [T] [t] |  
                        | 8 | CTS | in <-- |  | ; Reset ASCI I  [R] [r] |  |  
                        | 9 | NC | -- |  |  Connection cables ; Cross cables ( not included ) |  
 
                
                    
                        |  PK-2002 |  | ; Data imported into Excel cells from RS-232C output. |  
                        |  CB-BCD |  | ; Cannot be used in combination with RS-232C output. |  | 
        
            | 
                
                    
                        |  Display functions |  | 
                
                    Note ;
                        |  1/1 display | --> Displays the measured value as is. |  
                        |  1/2 display | --> Displays the measured value after halving it. |  
                        |  ×2 display | --> Displays the measured value after doubling it. |  With 1µm display and ×2 display, the lowest digit will be displayed as an even number.
 |