Model |
Standard |
Dia-shaped |
Insertion type |
Nominal size
|
Wafer type |
10 to 150mm
(15 mm min. for steam) |
15 to 80mm |
— |
Flange type |
15 to 300mm |
50, 80mm |
— |
Applicable tube size |
— |
— |
200 to 2000mm |
Flow
range
|
Fluid (water) |
0.2* to 2510m3/h (11 types)
(* Accuracy ±2% FS at 10 mm) |
0.8 to 172m3/h
(5 types) |
72 to 67800m3/h
(10 types) |
Gas (0.2 MPa air) |
2* to 15000m3/h (11 types)
(* Accuracy ±2% FS at 10 mm) |
— |
923 to 565000m3/h
(10 types) |
Steam (0.5 MPa
saturated steam) |
0.02 to 47.6t/h (10 types)
(15mm min.) |
— |
3.06 to 1790t/h
(10 types) |
Applicable fluid |
Liquid, gas, steam |
Liquid |
Liquid, gas, steam |
Operating temp. range |
–30 to +300°C
–30 to +460°C
(For high temperature of replaceable sensor) |
–10 to +300°C |
Flange standard |
JIS 10, 20, 30K ASME/JPI 150, 300 |
JIS 10K ASME/JPI 150 |
Max. operating pressure |
4.51MPa (Depends on flange standard and flange material.) |
Depends on flange standard. |
Accuracy |
±1% of reading or ±1% of full scale |
±1% of full scale |
Power supply |
DC-powered or battery-powered |
Body material |
SUS316 or SCS14A |
SUS304 |
Configuration |
Explosionproof or non-explosionproof,
IP66 (DC-powered), IP65 (battery-powered) |
Explosionproof or non-explosionproof, IP65 |
Output |
Analog, pulse
|