Pipe diameter (mm) |
25, 32, 40, 50, 65, 80, 100, 150, 200 |
Power supply voltage |
24 V DC ±10% or lithium-ion battery (battery life: approx. 10 years under the temperature of 20°C) |
Power consumption |
24 V DC, 1.5 W or less |
Target fluid |
Air (mainly factory air) or N2 (pipe diameter 25–80 mm) |
Fluid temperature |
-10°C to 60°C, RH90% or less |
Operating pressure |
< 1 MPa (gauge pressure) |
Range (actual flow rate) and accuracy |
Diameter (mm) |
Range (m3/h) |
Accuracy |
±2.0% of rate |
±5.0% of rate |
25 |
±0.6–35 |
±3.5–35 m3/h |
±0.6–3.5 m3/h |
32 |
±1.1–65 |
±6.5–65 m3/h |
±1.1–6.5 m3/h |
40 |
±1.3–80 |
±8–80 m3/h |
±1.3–8 m3/h |
50 |
±2.5–150 |
±15–150 m3/h |
±2.5–15 m3/h |
65 |
±4–240 |
±24–240 m3/h |
±4–24 m3/h |
80 |
±5–300 |
±30–300 m3/h |
±5–30 m3/h |
100 |
±10–500 |
±50–500 m3/h |
±10–50 m3/h |
150 |
±24–1200 |
±120–1200 m3/h |
±24–120 m3/h |
200 |
±40–2000 |
±200–2000 m3/h |
±40–200 m3/h |
|
Flow rate conversion accuracy: |
FWD025–080: ±2.5% or rate (at 500 kPa, 25°C, dry air)
FWD100–200: ±2.0% or rate (at ≥ 300 kPa) |