AC current output
|
Phase current output (effective value)
|
0-40A
|
Phase current max. output power
|
420VA
|
Maximum parallel current output (effective value)
|
0~120A
|
Maximum parallel power output
|
900VA
|
Long-term allowable working value of phase current (effective value)
|
10A
|
Allowable working time of maximum current
|
10s
|
Frequency range(fundamental wave)
|
20-1000Hz
|
Harmonic wave times
|
1-20 times
|
Accuracy
|
0.2%
|
AC voltage output
|
Phase voltage output (effective value)
|
0~120V
|
Line voltage output (effective value)
|
0~240V
|
Phase voltage/Line voltage output power
|
80VA/100VA
|
Frequency range(fundamental wave)
|
20-1000Hz
|
Harmonic wave times
|
1-20 times
|
Accuracy
|
0.5%
|
DC voltage output
|
Phase voltage output range
|
0~±160V
|
Line voltage output range
|
0~±320V
|
Phase voltage/Line voltage output power
|
70VA/140VA
|
Accuracy
|
0.2%
|
DC current output
|
Output range
|
0-±10A /phase, 0-±30A /parallel
|
Maximum output load voltage
|
20V
|
Accuracy
|
0.2%
|
Binary input (7channels)
|
Idle contact
|
1~20mA, 24V (DC)
|
Electric potential contact
|
"0":0- +6V;
"1": +11 V- +250V
|
Binary output (2pairs)
|
DC 220V/0.2A
AC 220V/0.5A
|
Time measurement
|
Measurement range: 0.1ms-9999s accuracy 0.1ms
|
Size
|
400×300×180mm³
|
Weight
|
22kg
|
Supply power
|
AC 220V±10%,50/60Hz
|
Environmental temperature
|
-10℃ ~ +50℃
|