Test voltage
500 V, 1,000 V, 2,500 V, 5,000 V with fast selection. From 250 V to 5 k V selectable in 25 V, 100 V or 500 V steps. DC, negative.
Maximum resistance reading
5 TΩ @ 1 kV up to 5 kV.
1 TΩ @ 500 V up to 1 kV.
500 GΩ @ 250 V up to 500 V.
DC Voltmeter
10 V up to 1000 Vdc.
Accuracy: ±(5% of reading + 3 digits).
AC voltmeter
10 V up to 1000 Vr.m.s.
Accuracy: ±(5% of reading + 3 digits).
Overvoltage category
CAT. III - 600 V.
Leakage currente measurement
1 nA up to 3 mA ±(10% of reading + 3 digits).
Capacitance measurement
50 nF up to 10 µF @ 500 V.
50 nF up to 5 µF @ 1,000 V.
30 nF up to 2 µF @ 2,500 V.
30 nF up to 1 µF @ 5,000 V.
Accuracy: ±10% of reading ± 3 digits.
Short circuit current
Max. 3 mA.
Test voltage accuracy
± 3% of nominal test voltages on GΩ.
Insulation tester basic accuracy
± 5% of reading from 1 MΩ up to 1 TΩ @ 5 kV.
± 20% of reading from 1 TΩ up to 5 TΩ @ 5 kV.
((for lower test voltages, the upper limit will be reduced proportionally).
± 20% of reading from 10 kΩ up to 100 kΩ.
± 10% of reading from 100 kΩ up to 1 MΩ.
Advanced features
Automated Polarization Index calculation.
Automated Dielectric Absorption Ratio calculation.
Programmable Pass-Fail test.
Step Voltage Test.
4,000 Readings memory.
Switchable filter to remove external noise interference.
Built-in printer
Prints elapsed time, actual voltage and resistance measured each 15 seconds.
Interface
USB.
Built-in chonometer
Shows elapsed time in mm:ss format. Count starts automatically for each measurement.
MegaLogg2 Software
Friendly, easy to use software. Tests are represented in graphic and tabular views. With automatic report generator, including the operator's commentaries.
Environmental protection
IP54 (with closed lid).
Safety Class
In accordance with IEC 61010-1.
E.M.C.
In accordance with IEC 61326-1.
Electro magnetic irradiation immunity
In accordance with IEC 61000-4-3.
Electrostatic immunity
In accordance with IEC 61000-4-2.
Power supply
Internal rechargeable (LiFePO4 12.8 V - 6000 mAh).
Battery charger
12 V - 2 Amp.
Operating temperature range
-5°C to 50°C.
Storage temperature range
-25°C to 70°C.
Humidity range
95% UR (non condensing).
Weight
Approx. 4.3 kg.
Dimension
340 x 295 x 152 mm.