Model: PRS-812B Specifications |
Range |
Optimal Resistance Range from 0.10Ohms to 1.00 TeraOhms |
Open Circuit Current |
<4ma @ 100 Volts |
Number of Data Points in Memory |
0 - 120 |
Dimensions |
4.5in x 7.5in x 2.0in |
Weight |
18oz |
Ohms Display indicators |
Ω, KΩ, MΩ, GΩ and TΩ. Includes 19-segment analog scale (1-10 with 0.5 indication) with x1, x10, & x100 multipliers. |
Test Voltages |
Automatic Mode |
0.01Volts to 10Volts Variable: 1.00E-1Ohms to 1.00E+4Ohms |
Constant Voltage |
10Volts (+/- <0.2Volts): 1.00E+4Ohms to <1.00E+6Ohms
100 Volts: +/- 1.00E+12Ohms |
Manual Mode |
0.01Volts to 10Volts Variable: 1.00E-1Ohms to <1.00E+5 Ohms
10Volts (+/- <0.2Volts): 1.00E+2Ohms to 1.00E+9 Ohms
100Volts: +/- 1.00E+12 Ohms |
Accuracy |
Overall |
+/- <5% at Ambient Conditions (23°C and 30°rF) |
Specific Range Tolerances: |
1.0E-1Ohms to 1.0E+1Ohms: +/- 5% Corrected for Test Lead Resistance
1.00E+1Ohms to 1.00E+12Ohms: +/- 2.0% with 10-foot Test |
Resistance Range Electrification Period |
0.10Ohms to <1.00E+06Ohms: <3.0Seconds