Instrument Standards |
BS ISO 10816-1 : 1995 + A1 : 2009, BS ISO 10816-3 : 2009, BS ISO 10816-7 : 2009 |
Range: (Integration = Acceleration) |
Low: 0.005 – 20.0m/s-2 / 0.00051 – 2.04g, High: 0.05 – 200.0m/s-2 / 0.0051 – 20.4g |
Range: (Integration = Velocity) |
Low: 0.06 – 250mm/s, High: 0.6 – 2500mm/s |
Range: (Integration = Displacement) |
Low: 4.0 – 16500um/s, High: 40.0 – 165000um/s |
Measurement Channels |
One |
Parameters |
Acceleration: Arms, Aeq, Amax, Peak, Crest Factor, Velocity: Vrms, Veq, Vmax, Peak,
Crest Factor, Displacement: Drms, Deq, Dmax, Peak to Peak, Crest Factor |
Alarms |
Machine, Pump, Bearing |
Linear Operating Range |
72dB |
Frequency Weighting |
WFL – 2Hz to 8kHz, WLP – 2Hz to 1kHz, WHP – 1kHz to 8kHz |
Memory |
Flash memory storing up to 992 recordings |
Transducer |
Castle KD1011, 100mV/g |
Noise Floor |
<0.002 m/s-2 – Low Range, <0.020 m/s-2 – High Range |
Display |
Full Colour Graphic OLED Display (160 x 128) |
Batteries |
NiMH re-chargeable cell pack Typically 10 hours continuous use |