Sampling method
|
Pump suction
|
Gas type
|
NH3 H2S CO O2 combustible gases, other gases are customized
|
Measure range
|
0-100ppm, 0-100ppm, 0-1000ppm, 0-30%VOL, 0-100%LEL, other measure ranges are customized
|
Resolution
|
0.1ppm, 0.1ppm, 1ppm, 0.01%VOL, 1%LEL
|
Response time
|
≤10 seconds
|
Precsiion
|
≤±2%F.S
|
Language
|
English(Other languages can be customized)
|
Automatically test and calibrate after power-on
|
Including reset, maximum value (MAX), minimum value (MIN), STEL, TWA value
|
Unit
|
PPM and mg/m³ can be switched
|
Disaply
|
monochrome graphics (160 x96) ,screen can be automatically flipped
|
Backlight
|
The backlight time can be manually set, and will be turned on automatically when an alarm is issued
|
Data record
|
Can store 100,000 sets data, the storage interval is adjustable from 5 to 3600 seconds, data can be exported
|
Alarm
|
95dB buzzer (@30cm), vibration alarm and flashing red LED and alarm status indication on the screen, alarm latched; diagnostic alarm and battery undervoltage alarm, pump block alarm; man down alarm, with early warning and optional real-time remote Bluetooth notification function
|
Battery
|
3.7V rechargeable lithium battery, battery capacity 2200mA
|
Working hours
|
More than 15 hours in continuous pumping mode
|
Charger
|
Travel charger with DC interface, charging time ≥ 4 hours
|
Explosion-proof grade
|
IECEX/ATEX(II IG Ex ia IIC T4
CNEX:Ex ia IIC T4 Ga
|
Certification
(EU regulations)
|
2004/108/EC(EMC)
1995/5/EC(Radio)
94/9/EC(ATEX)
|
Protection grade
|
IP67/IP68
|
Working temperature
|
-20ºC~+50ºC
|
Humidity
|
0~90%RH(no condensation)
|
Environmental pressure
|
86~106Kpa
|
Size
|
157*84.5*59.5mm (including back clip/water trap filter) (length * width * height)
|
Weight
|
365g (including battery, belt clip and filter)
|
Bluetooth function(Optional) |
NH3 H2S CO O2 %LEL Multi Gas Detector data can be transmitted to the mobile phone or PC in real time |