Model
|
Benchtop Spectrophotometer YS6060
|
Benchtop Spectrophotometer YS6010
|
Optical Geometry
|
Reflective : d/8°(diffused illumination, 8-degree viewing angle);SCI&SCE / SPIN&SPEX;Including / excluding UV measurements
Transmissive : d/0°(diffused illumination, 0-degree viewing angle);SCI&SCE / SPIN&SPEX;Including / excluding UV measurements
Comply to standard CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
|
Application
|
It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.
|
Integrating Sphere Size
|
Φ154mm
|
Light Source
|
360~780nm Combined LED Lamp, 400nm Cut-off light source,420nmCut-off light source
|
360~780nm Combined LED Lamp, 400nm Cut-off light source
|
Wavelength Range
|
360~780nm
|
Spectral Separation Device
|
Concave grating
|
Detector
|
256 Image Element Double Array CMOS Image Sensor
|
Wavelength Range
|
360~780nm
|
Wavelength Pitch
|
10nm
|
Half Bandwidth
|
10nm
|
Reflectance Range
|
0~200%
|
Measuring Aperture
|
Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive : Φ30mm/Φ25mm;
|
Reflective : Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive : Φ30mm/Φ25mm;
|
Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
|
Specular Component
|
Reflectance: SCI&SCE Transmittance: SCI&SCE
|
Color Space
|
CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
|
Color Difference Formula
|
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter)
|
Other Colorimetric Index
|
WI (ASTM E313, CIE/ISO, AATCC, Hunter),
YI (ASTM D1925, ASTM 313),
TI (ASTM E313, CIE/ISO),
MI (Metamerism Index),
Staining Fastness, Color Fastness, Color Strength,
Opacity,8° Glossiness, Gardner Index, Pt-Co Index, 555 Index,
|
Observer Angle
|
2°/10°
|
Illuminant
|
D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
|
Displayed Data
|
Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset
|
Measuring Time
|
About 3s (Measure both SCI & SCE about 6s)
|
Repeatability
|
Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
|
Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
|