| Sampling Method |
Extractive Sample Draw |
| Gases Detected |
Methyl Bromide (CH3Br) |
| Range1 |
0 – 10 ppm
0 – 30 ppm |
| Accuracy |
± 10 % |
| Operating Temperature |
-20 to +50 ºC
-4 to +122 ºF |
| Sensor Type |
Self Checking Renewable Electrochemical Sensor |
| Sensor Life |
5 to 8 years under Normal Conditions |
| Gas Concentration Indicator |
Built-in LCD Digital Display, Back Lit
Displays, Gas Name, ppm Concentration, AL1, AL2, System Fault Messages |
| Signal Outputs |
4-20 mA Analog Output
Alarm Level 1 – SPDT AC 125 V, 0.3 A max
Alarm Level 2 – SPDT DC 30 V, 1.0 A max Resistive Load
Fault – SPDT Fail-Safe |
| Sampling Distance2 |
100 ft
33 m |
| Sample Pump |
Electromagnetic DC Diaphragm Pump |
| Power Requirements |
2.0 A
24 VDC |
| Width |
10.0 in
254 mm |
| Height |
6.5 in
165.1 mm |
| Depth |
8.0 in
203.2 mm |
| Weight |
6.2 lbs
2.8 kg |
| Enclosure |
| IP 65 Nema 4X Water Resistant |
|
| Optional Extras |
Enclosure: Class 1, Div 1, Group B, C & D Explosion Proof |
| Country of Origin |
USA |
| Harmonized Tariff Code |
8531.10.0045 |