Trang TMĐT chính thức của công ty cổ phẩn công nghệ đỉnh cao TTech
Construction
Extruded FR-ABS with ABS end caps, epoxy resin. Tungsten emitters at 10 mm pitch.
Dimensions
20 x 69 mm (W x H). Available Lengths: minimum 200 mm, then in 100 mm steps to 4000 mm. Active length is 70 mm less than overall length. A 60 mm option is available for specialist applications.
Cable
2 m of 60 kV cable. Longer lengths can be specified at time of order. Cable terminates in HV connector. Protective nylon conduit on cable. Minimum bend diameter 100 mm.
Safety
170 MOhm resistance for safe operation.
Environmental
Clean, dry and oil-free location. Temperature: 0 - 60 °C, 70 % rH non-condensing max.
Generator
7130 for 30 kV generators. 7150 for 50 kV generators. 7160 for all IONFIX™ generators. State generator model at time of order.
Certification
CE.
Options
7130-/50-/60-T5: Tungsten emitters at 5 mm pitch, 400 Mohm resistance. Emitter Mask (Part No. 715003) to cover live emitter pins where they are not needed - see separate Datasheet. 1 m length to cut as required. 90° cable outlet.
Liên hệ