Types |
For high temperature 2-color type radiation thermometer |
For medium temperature 2-color type radiation thermometer |
Models |
IR-CZQH7 |
IR-CZQW2 |
Measuring Wavelength |
0.9/1.55μm |
0.9/1.35/1.55μm |
Detecting element |
Si/InGaAs |
Si/InGaAs/InGaAs |
Accuracy Rating |
Below 1500°C…±5°C
1000°C or more, below 1500°C…±0.5% of measured value
1500°C or more, below 2500°C…±0.6% of measured value
2500°C or more…±1.0% of measured value |
Below 1000°C…±5°C
1000°C or more, below 1500°C…±0.5% of measured value
1500°C or more…±0.6% of measured value |
Response Time |
2 to 15ms |
Distance Factor |
200 with field spot φ10mm |
200 |
Focusing System for Spot |
Finder focusing |
Analog Output |
4 to 20mA DC Isolated output
Load resistance…750Ω or less |
Communication Interface |
RS-485 transmits measured data, transmits and receives various parameters |
Power Supply |
24V DC (Allowable voltage fluctuation range・・・22 to 28V) |
Power Consumption |
Max. 2.4VA |
Connection |
Dedicated connector connection, terminal connection |