HR Model |
Range (nm) |
Grating g/mm |
Res. (nm)-25µm slit |
Res. (nm)-14µm slit |
STN-HR-UV3 |
200-300 |
2400 |
0.21 |
0.14 |
STN-HR-UV3b |
300-400 |
2400 |
0.21 |
0.14 |
STN-HR-UV4 |
200-340 |
1800 |
0.30 |
0.20 |
STN-HR-VIS |
350-750 |
600 |
1.20 |
0.80 |
STN-HR-NIR |
500-900 |
600 |
1.20 |
0.80 |
STN-HR-NIR2 |
900-1075 |
1200 |
0.80 |
0.40 |
STN-HR-NIR3 |
750-850 |
1800 |
0.30 |
0.20 |
STN-HR-NIR4 |
500-580 |
2400 |
0.12 |
0.08 |
|
|
|
|
|
HR-X Models |
Range (nm) |
Grating g/mm |
Nm/pixel disp. |
Res. (nm, 7µm slit) |
STN-HR-X-UV1 |
240-300 |
2400 |
0.029 |
0.05 |
STN-HR-X-UV2 |
300-360 |
2400 |
0.029 |
0.05 |
STN-HR-X-UV3 |
360-420 |
2400 |
0.029 |
0.05 |
STN-HR-X-VIS1 |
420-480 |
2400 |
0.029 |
0.05 |
STN-HR-X-VIS2 |
480-540 |
2400 |
0.029 |
0.05 |
STN-HR-X-VIS3 |
540-600 |
2400 |
0.029 |
0.05 |
STN-HR-X-VIS4 |
600-650 |
2400 |
0.024 |
0.05 |
STN-HR-X-VIS5 |
650-700 |
2400 |
0.024 |
0.04 |
STN-HR-X-NIR1* |
700-800 |
1200 |
0.059 |
0.09 |
STN-HR-X-NIR2* |
800-900 |
1200 |
0.059 |
0.09 |
STN-HR-X-NIR3* |
900-1000 |
1200 |
0.059 |
0.09 |
STN-HR-X-NIR4* |
1000-1100 |
1200 |
0.059 |
0.09 |
*STN-HR-X-NIR models are all built with center range X00 to Y00 with 5-10nm on either side unless otherwise specified. Most HR-X models can be shifted at no charge.È |
|
|
|
|
|
LIBS/Laser Standard (LSR) and high Resolution (LHR) spectrometer models (UV-VIS-NIR) |
LSR Models |
Range (nm) |
Grating g/mm |
Res. (nm, 14 µm slit) |
STN-LSR-UV2 |
200-400 |
2400 |
0.20 |
STN-LSR-VIS4 |
400-600 |
2400 |
0.20 |
STN-LSR-VIS4b |
600-800 |
1800 |
0.20 |
STN-LSR-VIS3b |
800-1000 |
1800 |
0.20 |
|
|
|
|
|
LHR Models |
Range (nm) |
Grating g/mm |
Res. (nm, 7µm slit) |
STN-LHR-UV3 |
200-300 |
2400 |
0.10 |
STN-LHR-UV3b |
300-400 |
2400 |
0.10 |
STN-LHR-VIS3 |
400-500 |
1800 |
0.10 |
STN-LHR-VIS3b |
500-600 |
1800 |
0.10 |
STN-LHR-VIS3c |
600-700 |
1800 |
0.10 |
STN-LHR-NIR3 |
700-800 |
1800 |
0.10 |
STN-LHR-NIR2 |
800-975 |
1200 |
0.20 |
Other slit sizes available to fit resolution needs.
STN-LSR and STN-LHR models come with Jack-In trigger, DLENS, & High Resolution Calibrations.
When multiple units are ordered together, start and stop WLs is guaranteed for continuous measurement. |
|
|
|
|
|
NIR-High Resolution spectrometer models (DwarfStar + RedWave) |
|
NIR Models |
Range (nm) |
Res. (nm, 25µm slit) |
|
STN-DS-InGaAs-512-NIR2 |
1250-1575 |
1.3 |
|
STN-DS-InGaAs-512-NIR2b |
1150-1475 |
1.3 |
|
STN-DS-InGasAs-512-NIR3-HR/
STN-WDM-Wave-NIR3-HR (Telecom) |
1530-1605 |
0.4 |
|
STN-DS-InGaAs-1024-NIR3-HR/
STN-WDM-Wave-NIR3-HR (Telecom) |
1500-1640 |
0.40 |
|
STN-HR-X-NIR-InGaAs |
1500-1600 |
0.2 (7 um slit) |