| Model | CPV-GAas-30-CP-AR | CPV-GAas-40-CP-AR | 
        
            | Exterior dimension | 485 * 600 * 600 mm (W*H*D)(including projected parts) | 
        
            | Standard Channel | 6 channel / module / 72W (max 30 channel/set) | 5 Channel/module/250W (max 40 channel/set) | 
        
            | Maximum control Module | 5 module / 360W | 8 module / 2 KW | 
        
            | Method of Test setting | Set channel (start/stop) ; each channel single control ,can set different Current & data | 
        
            | CH. Output volt/current range | AC 0~4V/ 0~3000mA(1mA/Step)/channel | AC 0~5V/ 0~10A(1V/Step)/channel | 
        
            | Operation mode | CC | 
        
            | sample rate & com interface | 1Sec~59:59mm:ss (Sample to Controller) , 5sec (Sample to PC) & RS485 or RS232 | 
        
            | Continuous Mode ON-OFF Mode
 | Select Continuous Mode Allow Switch ON-OFF Pulse Set(0~59,59mm:ss), cycle set function(decimal)
 | 
        
            | Current Setting / Max test time | Bias & Test current –(setting of bias positive current /test positive current setting)/9999.9Hr | 
        
            | Data reading & link number of machines | read /record value of the voltage& temp. of channel and T/H values of each Chamber / max 32 Set | 
        
            | Output & indicator | 1%±2mA & 0.1V/1mA | 
        
            | Voltage / Current values Conversion curve | record the voltage and Temperature values of each Channel can convert the Curve | 
        
            | Voltage /Current/Temp. Analysis | Recording of the start /sample/ end time of voltage/ temp. | 
        
            | Excel report conversion | Set condition data, measurement data and voltage shortage data converted as Excel file | 
        
            | Power Source | AC 220V/10A , 50/60Hz | AC 220V/20A , 50/60Hz |