IsoSplitter - Split One Analog Signal Into Two Isolated DC Outputs
|
- Lifetime Warranty on API Modules
- LoopTracker® I/O LEDs
- Hot-Swappable Plug-In Design
- Zero and Span Output Calibration
- Push to Test Output
- Full I/O/Power Isolation
Click on PDF links below
for product information |
Literature and Links
UL Approvals
API modules USA
API modules Canada
APD modules USA
APD modules Canada
|
Reference Info
Ground Loops
RFI/EMI
LoopTracker and Output Test
Sink vs Source
Applications
Split a 4-20mA RTD signal
Split a 4-20mA HVAC signal
Split a 4-20mA flowmeter signal
Split a 4-20mA pellet flowmeter signal
Drive three 4-20mA SCR signals
|
How to Order
- Select a model
- See data sheet for ordering info and options
- Note that options affect pricing
- Request a quote via chat or call us
- 2-5 day typical lead time + shipping time
- 5-10 day lead time for quantities of 5 or more + shipping time
- To place your order
|
Model |
Input/Output |
Features |
Product |
IsoSplitter® Signal Splitter
1 DC Input to 2 DC Outputs
Factory Configured
APD 4930 from $309
Open Datasheet
Download Datasheet
Open Features
Download Features
|
Specify input range
0-10 mVDC to 100 VDC
±50 mV to ±10 VDC
0-1 mADC to 0-50 mADC, 4-20 mADC
Specify output range for each channel
2 independent channels
0-1 V to 0-20 V
±1 V to ±10 V
0-1 mA to 0-25 mA, 4-20 mA
|
- Removable plugs
- Output LoopTracker LEDs
- Selectable sink/source mA input
- 15 V input loop power supplies
- Sourcing mA output (sinking optional)
- 20 V output loop power supplies
- Sinking mA outputs optional
- Output test/manual override terminals
- Full I/O/power isolation
- DIN rail mount
- 22.5 mm wide
- Universal power 85-265 VAC, 60-300 VDC
- D option for 9-30 VAC/VDC power
|
APD 4930 DC IsoSplitter
|
IsoSplitter® Signal Splitter
1 DC Input to 2 DC Outputs
Factory Configured
APD 4393 from $475
Open Datasheet
Download Datasheet
|
Specify input range
Factory Configured
0-10 mVDC to 100 VDC
±50 mV to ±10 VDC
0-1 mADC to 0-50 mADC, 4-20 mADC
Specify output range for each channel
2 independent channels
0-1 V to 0-20 V
±1 V to ±10 V
0-1 mA to 0-25 mA, 4-20 mA
|
- Removable plugs
- I/O LoopTracker LEDs
- Selectable sink/source mA input
- 15 V input loop power supplies
- Selectable sink/source mA output
- 20 V output loop power supplies
- Output test button
- Full I/O/power isolation
- DIN rail mount
- 45 mm wide
- Universal power 85-265 VAC, 60-300 VDC
- D option for 9-30 VAC/VDC power
|
APD 4393 DC IsoSplitter
|
IsoSplitter® Signal Splitter
1 RTD Input to 2 DC Outputs
Factory Configured
APD 1393 from $499
Open Datasheet
Download Datasheet
|
Specify RTD type and temperature range
Factory configured
10 Ω to 2000 Ω RTD including
100 Ω 0.00385α
100 Ω 0.00391α,
10 Ω Cu
1000 Ω Ni-Fe
120 Ω Ni or special
Specify output range for each channel
2 independent channels
0-1 V to 0-20 V
±1 V to ±10 V
0-1 mA to 0-25 mA, 4-20 mA
|
- One RTD input
- Two independent DC output channels
- I/O LoopTracker LEDs
- Selectable sink/source mA output
- 20 V output loop power supplies
- Output test buttons
- Full I/O/power isolation
- Removable plugs
- DIN rail mount
- 45 mm wide
- Universal power 85-265 VAC, 60-300 VDC
- D for 9-30 VDC, 10-32 VAC power
|
APD 1393
|
IsoSplitter® Signal Splitter
1 Potentiometer Input to 2 DC Outputs
Factory Configured
APD 3393 from $499
Open Datasheet
Download Datasheet
|
Use any full range 100 Ω to 1 MΩ potentiometer
Specify output range for each channel
2 independent output channels
0-1 V to 0-20 V
±1 V to ±10 V
0-1 mA to 0-25 mA, 4-20 mA
|
- One potentiometer input
- Two isolated DC output channels
- Selectable sink/source mA output
- 20 V output loop power supplies
- I/O LoopTracker LEDs
- Output test buttons
- Full I/O/power isolation
- Removable plugs
- DIN rail mount
- 45 mm wide
- Universal power 85-265 VAC, 60-300 VDC
- D for 9-30 VDC, 10-32 VAC power
|
APD 3393 Potentiometer IsoSplitter
|
IsoSplitter® Strain Gauge Signal Splitter
1 Strain Gauge Input to 2 DC Outputs
Factory Configured
APD 5393 from $499
Open Datasheet
Download Datasheet
|
Specify input range
Factory configured for one 350 Ω (or greater)
strain gauge, load cell or bridge
Strain gauge mV range: 1 mV to 2000 mV
Specify mV/V or mV range
mV/V sensitivity X excitation voltage = total mV range
Specify excitation voltage
4 to 10 VDC excitation at 30 mA
Specify output range for each channel
2 independent channels
0-1 V to 0-20 V
±1 V to ±10 V
0-1 mA to 0-25 mA, 4-20 mA
|
- One strain gauge input
- Two independent DC output channels
- I/O LoopTracker LEDs
- Selectable sink/source mA output
- 20 V output loop power supplies
- Output test buttons
- Full I/O/power isolation
- Removable plugs
- DIN rail mount
- 45 mm wide
- Universal power 85-265 VAC, 60-300 VDC
- D for 9-30 VDC, 10-32 VAC power
|
APD 5393 Strain Gauge IsoSplitter
|
IsoSplitter® AC Signal Splitter
1 AC Input to 2 DC Outputs
Factory Configured
APD 6393 from $499
Open Datasheet
Download Datasheet
|
Specify mVAC, VAC or mAAC input range
True RMS
0-50 mVAC to 0-300 VAC
0-1 mAAC to 0-1000 mAAC
Input frequency: 40 Hz to 1000 Hz sinusoidal
Specify output range for each channel
2 independent output channels
0-1 V to 0-20 V
±1 V to ±10 V
0-1 mA to 0-25 mA, 4-20 mA
|
- One AC input
- Two isolated DC output channels
- I/O LoopTracker LEDs
- Selectable sink/source mA output
- 20 V output loop power supply
- Output test buttons
- Full I/O/power isolation
- Removable plugs
- DIN rail mount
- 45 mm wide
- Universal power 85-265 VAC, 60-300 VDC
- D for 9-30 VDC, 10-32 VAC power
|
|