NOTE- |
- All CRVW3 dataloggers are tested and guaranteed to meet the following electrical specifications in a -40° to +70°C non-condensing environment.
- The base -NA option and -RF422 option are CE approved, but the -RF451, -RF407, and
-RF412 options are not CE approved.
|
Operating Temperature Range |
- -40° to +70°C
- Non-condensing environment
|
Processor |
ST ARM CORTEX-M4 (32-bit with hardware FPU, running at 144 MHz) |
Data Storage |
16 MB serial flash, up to 420,000 records (single channel), up to 160,000 records (3 channels) |
Real-Time Clock Accuracy |
±3 min. per year |
Measurement Interval Range |
1 s to 1 day |
USB Micro B |
Direct connect to PC (supplies power for configuration and data collection), 2.0 full speed, 12 Mbps |
Configuration |
Software configurable, no programming required |
Compliance |
RoHS |
Warranty |
One year against defects in materials and workmanship |
Weatherproof Enclosure Rating |
NEMA 4X (IP66) with proper use of cable entry points |
Enclosure Mounting |
Stainless-steel universal mount for pole/wall mount (optional) or plastic mounting tabs (included) |