| Typ: | B1 | B2 | B3 | 
        
            | Measuring range | ±3g (ca.±30m/s2) | ±10g (ca.±100m/s2) | ±50g (ca.±500m/s2) | 
        
            | Resolution | <10-3g | <5·10-3g | <2·10-2g | 
        
            | Frequency range | 0...160Hz | 0...350Hz | 0...550Hz | 
        
            | Linearity deviation | <0,5% | 
        
            | Transverse sensitivity | <1% | 
        
            | Mechanical overload resistance in direction of measurement | 10 000 g (approx. 100 000 m/s2) | 
        
            | Nominal supply voltage (regulated) | UbN = 5Volt | 
        
            | Permissible range of supply voltage | Ubz = 3V ... 6V | 
        
            | Current drawn at Ub = 5V | approx.1mA | 
        
            | Degree of protection | IP65 | 
        
            | Operating temperature | -40°C ... +85°C (125°C optional) | 
        
            | Storage temperature | -45°C ... +90°C (125°C optional) | 
        
            | Weight (in metal housing without cable) | approx. 23 grams | 
        
            | Standard electrical connection | 3 highly flexible, color-coded wires ø1mm, length approx. 18 cm (special lengths on request) | 
        
            | Alternative electrical connection | 0.5m strong, flexible, shielded cable ø2.1mm (special lengths on request) 3 flexible, color-coded wires with Teflon insulation for extended temperature range
 | 
        
            | Values for analog DC output at UbN = 5 Volt | 
        
            | Sensitivity | approx. 140mV/g | approx. 30mV/g | approx. 7,5mV/g | 
        
            | Temperature drift of sensitivity | <+6·10-2  % / K | 
        
            | Temperature drift of zero point | <0.1mV/K | 
        
            | Zero offset at Ub=5V | 2.5±0.1Volt - generally: 0.5Ub±4% | 
        
            | Output impedance | 10 kOhm |