| Typ |
NG2 |
NG3 |
NG4 |
| Measuring range |
±10 degrees |
±30 degrees |
±80 degrees |
| Resolution |
<0.001 degrees |
<0.003 degrees |
<0.01 degrees |
| Linearity deviation |
<0.1% of measuring range |
| Transverse sensitivity |
<0.5% at 45° tilt |
| Settling time |
approx. 0.3 seconds |
| Mechanical overload resistance |
10 000 g (approx. 100 000 m/s2) |
| Supply voltage UbN (regulated) |
5V |
| Permissible supply voltage range Ubz |
3V ... 6V |
| Current drawn at Ub = 5V |
approx.1mA |
| Degree of protection |
IP65 |
| Operating temperature |
-40°C ... +85°C |
| Storage temperature |
-45°C ... +90°C |
| Weight (without clamping ring or cable) |
approx. 110 grams |
| Electrical connection |
0.5m shielded cable Ø 4.6mm |
|
Values for analog DC output at UbN = 5 Volt
|
| Sensitivity |
approx.10mV/degree |
approx.7mV/degree |
approx.4.5mV/degree |
| Temperature drift of sensitivity |
<-0.12%/K |
| Temperature drift of zero point |
<0.01mV/K |
| Zero offset at Ub=5V |
(2,5±0,1)Volt - generally: 0,5Ub±4% |
| Output impedance |
10 kOhm |