Model |
OXITEC5000 Sensor |
OXITEC5000 Ex Sensor |
Sensitivity |
Below 1ppm O2 |
Below 1ppm O2 |
Accuracy |
±0.2%(from measured value) |
±0.2%(from measured value) |
Allowable Pressure |
-50~+4000mbar |
-50~+4000mbar |
Velocity |
0~50m/sec |
0~50m/sec |
Allowable Temperature |
Around:-40~+80℃
Temperature inside the exhaust gas pipe.:
Max.600℃(Standard)
Max.1000℃(Heat resistant model for middle high temperature)
Max.1400℃(Heat resistant model for high temperature) |
Around:-40~+80℃
Temperature inside the exhaust gas pipe.:
Max.500℃(Standard)
Max.1400℃(Heat resistant model for high temperature) |
Enclosure Rating |
IP65 |
IP65 |
Probr Material |
316SS
Option:Hastelloy、V4A、Incoloy、Protec |
316SS
Option:Hastelloy、V4A、Incoloy、Protec |
Responsiveness |
0.5sec(about Velocity:10m/sec) |
0.5sec(about Velocity:10m/sec) |
Cable length |
Max.150m |
Max.150m |