First Class Anemometers for Wind Turbine Testing and Wind Farm Site Assessment (Wind Assessment): |
Type
|
Output Signal Type/Range
|
Resolution
|
Power Supply Required
|
Additional Features
|
Typical Applications
|
A100L2
|
0..1500Hz = 0..150Knots
(10Hz per Knot nominal)
|
0.05m
|
6.5 to 28V DC powered
(@1.5mA typical)
|
First Class, Low power,
Analog/Voltage Output:
0..2.5v = 0..150Knots nominal
[for higher output voltage/signal,
see Porton A100 & A100H models below]
|
Datalogger/AWS/WindAssessment
|
A100LK
|
0..1500Hz = 0..150Knots
(10Hz per Knot nominal)
|
0.05m
|
4.75 to 28V DC powered
(@1mA typical)
|
First Class, Low power
|
Datalogger/AWS/WindAssessment
|
A100LM
|
0..750Hz = 0..75m/s
(10Hz per m/s nominal)
|
0.1m
|
4.75 to 28V DC powered
(@1mA typical)
|
First Class, Low power
|
Datalogger/AWS/WindAssessment
|
A100AC
|
2 pulses per revolution
(1.554Hz per m/s nominal)
|
0.625m
|
No power required
|
First Class, low-level AC output signal,
optimal cosine response
|
Datalogger/AWS/WindAssessment
|
A100R/K
|
1 pulse per revolution
(1.287m wind-run = 0.777Hz per m/s nominal)
|
1.25m
|
No power required
|
First Class, reed-switch transducer,
optimal cosine response
|
Datalogger/AWS/WindAssessment
|
|
Other Anemometers: |
Type
|
Output Signal Type/Range
|
Resolution
|
Power Supply Required
|
Additional Features
|
Typical Applications
|
A100 Porton
|
analog/voltage signal
0..10V = 0..100Knots
(nominal)
|
0.05m
|
10 to 30V DC powered
|
High-Level Analog/Voltage Output:
0..10v = 0..100Knots nominal
(NO pulse/frequency output signal)
|
Datalogger/AWS/PLC/Industrial
|
A100H Porton
|
analog/voltage signal
0..7.5V = 0..75m/s
(nominal)
|
0.1m
|
10 to 30V DC powered
|
High-Level Analog/Voltage Output:
0..7.5v = 0..75m/s nominal
(NO pulse/frequency output signal)
|
Datalogger/AWS/PLC/Industrial
|
A100M
|
0..750Hz = 0..75m/s
(10Hz per m/s nominal)
|
0.1m
|
10 to 30V DC powered
(@35mA max)
|
Anti-Surge
|
Industrial/control/PLC
|
A100K
|
0..1500Hz = 0..150Knots
(10Hz per Knot nominal)
|
0.05m
|
10 to 30V DC powered
(@35mA max)
|
Anti-Surge
|
Industrial/control/PLC
|
A100S
|
1 pulse per revolution
(1.25m wind-run = 0.8Hz per m/s nominal)
|
1.25m
|
10 to 30V DC powered
(@35mA max)
|
Anti-Surge
|
Industrial/control/PLC
|
A100R
|
1 pulse per revolution
(1.25m wind-run = 0.8Hz per m/s nominal)
|
1.25m
|
No power required
|
reed switch transducer
|
Datalogger/AWS/PLC
|