Model |
ANGS015T |
ANGS030T |
ANGS045T |
ANGS060T |
ANGS090T |
ANGS120T |
ANGS180T |
ANGS240T |
|
Capacity |
15kVA |
30kVA |
45kVA |
60kVA |
90kVA |
120kVA |
180kVA |
240kVA |
|
AC input |
Number of phases |
Three-phase four-wire + PE |
|
Voltage |
Phase voltage: 220V ± 33V, line voltage: 380V ± 57V |
|
Frequency |
50/60Hz±3Hz |
|
AC output |
Number of phases |
Three-phase four-wire |
|
Mode |
Standard, Unbalanced |
|
Voltage |
Phase voltage: 0.0 ~ 300.0V |
|
Frequency |
45.00~65.00Hz |
|
Rated current |
220V |
22.7A |
45.4A |
68.2A |
90.9A |
136.3A |
181.8A |
272.7A |
363.6A |
|
Setting accuracy |
Voltage |
Resolution: 0.1V. Accuracy: 0.2%× reading +0.2%× Full scale |
|
Frequency |
Resolution: 0.01Hz. Accuracy: 0.05% |
|
Measurement accuracy |
Voltage |
Resolution: 0.1V. Accuracy: 0.2%× reading +0.2%× Full scale |
|
Frequency |
Resolution: 0.01Hz. Accuracy: 0.05% |
|
Current |
Resolution: 0.1A/1A. Accuracy: 0.3%× display +0.3%× Rated output |
|
Power |
Resolution: 0.1kW/0.01kW/0.001kW. Accuracy: 0.45%× reading +0.45%× Full scale |
|
Frequency stability |
≤0.02% |
|
Voltage distortion |
Linear load: THD<1% |
|
Transient recovery time |
20ms |
|
Three-phase phase difference |
Standard: 120±2°
Unbalanced: 0.0~359.9°, 0.1° adjustable |
|
|
Phase voltage crest factor |
1.41±0.1 |
|
Source voltage effect |
≤1% |
|
Load effect |
≤1% |
|
Overload capability |
105%< output ≤110%: Cut off the output within 15S; 110%< output ≤200%: Cut off the output within 5S
200%< output ≤300%: Cut off the output within 2S; 300%< output: Cut off the output immediately |
|
|
Impact resistance |
(1) Withstand 3 times the rated current for 2S; (2) Withstand inductive load with power not more than 0.5 times the rated power or start-up impact of rectifier load with crest factor less than 3.0 |
|
|
Protection |
IGBT overheating, IGBT overcurrent, transformer overheating, input overvoltage/undervoltage, output overvoltage/undervoltage, output phase failure, output overcurrent, output overload, output short circuit, bus anti-recharge |
|
|
Efficiency |
>86% |
|
Function |
Display |
8” LCD, resolution: 800 * 600 |
|
Output waveform |
Sine wave, harmonics (superimposed 2 ~ 40-th harmonics) |
|
Programming |
Low (zero) voltage through |
With, minimum response time 20ms |
|
Step |
Step: 9999 |
|
List |
100 steps: 999999 cycles |
|
Ramp |
100 steps: 999999 cycles |
|
Start ramp time |
0.0 ~ 99.9 seconds |
|
Online regulation |
Output voltage, output frequency in normal mode, online switching of waveform |
|
Memory |
Power-off memory, store the last output mode and parameters |
|
Shortcuts |
10 groups of common modes, 10 groups of harmonics |
|
Line voltage drop compensation |
0.000~0.500Ω |
|
Communication ports |
RS232 (standard), RS485 (optional), GPIB (optional), Ethernet (optional), Flip signal (standard) |
|
Remote control |
Analog control port (optional) |
|
DC output |
Voltage |
DC bus voltage |
|
Current |
16A |
33A |
49A |
65A |
98A |
131A |
196A |
262A |
|
Working environment |
Temp. |
0~40℃ |
|
Humidity |
20~90%RH |
|
Dimension W*H*D (mm) |
1000×1990×800 |
1200×1990×800 |
1200×1990×1000 |
|
Weight (KG) |
310 |
360 |
500 |
620 |
810 |
1060 |
1280 |
1380 |