LDM-110 |
LDM-110EX |
LDM-1000 |
LDM-1000EX |
Picture |
Go |
Go |
Go |
Go |
CAD file |
dxf |
dxf |
dxf |
dxf |
pdf |
pdf |
pdf |
pdf |
No. of Axes |
For Single |
Max. 2 |
Max. 5 |
Max. 3 |
Scanning cycle |
400 times/sec |
400 times/sec |
400 times/sec |
400 times/sec |
No. of
Averaging time |
1-2048
(16 steps) |
1-2048
(8 steps) |
1-2048(22 steps) at LDM-1000LS
1-1024(19 steps) at LDM-1000XY |
Measuring mode |
16 kinds |
8 kinds
(X,Y axis each) |
16 kinds + Optional edges measurement
per each axis |
Processing
function |
NG |
Average, Difference, Large dia. measurement, etc. |
Cable cover(Wall)
thickness
processing |
NG |
NG |
OK(by LDM-1000XY) |
Display device |
7 segment LED |
Graphic LCD |
7 segment LED |
No. of Display digit |
4-5 digits |
4-5 digits |
3-6 digits |
3-6 digits |
Processing
contents monitor |
NG |
NG |
OK |
OK |
Center position
monitor |
LED(8pcs) |
LED(8pcs)
(X,Y axis each) |
Graphic bargraph
per each axis |
LED(8pcs) per each axis |
No. of channel of
Recorder output |
1 |
1 |
1 channel per board(LDM-1000LS/XY) |
Recorder output
performance |
Max.+/-10V, Resolution 12bits(=approx.10mV/1bit),
Output impedance 100ohm(approx.),
Deviation/Absolute value switch over available |
Recorder output
gain |
1μm-1m/V(decade steps) |
0.1μm~1m/V(decade steps) |
Digital dia.
controller
connection |
OK |
OK |
NG |
NG |
Center value
setting |
5 digits |
5 digits |
6 digits |
6 digits |
High/Lo limit
tolerance setting |
4 digits |
4 digits |
6 digits |
5 digits |
High/Low limit
contact output |
1a contact(*2) |
1a contact(*2) per board(LDM-1000LS/XY) |
Contact rating: AC250V 2A(Resistance load) |
Error
contact output |
1b contact(Close when power OFF) |
1b contact(Close when power OFF)(Combined use by each board) |
Contact rating: AC250V 2A(Resistance load) |
Laser remote
terminal |
OK |
OK
(X,Y common) |
OK(each LDM-1000LS board) |
Hold terminal |
OK |
OK
(X,Y,P common) |
OK(each LDM-1000LS/XY board) |
Edge monitoring
function |
OK |
OK |
OK |
OK |
Self-diagnosis
mode |
OK |
OK |
OK |
OK |
Multi-point
calibration
function |
OK |
NG |
NG |
NG |
Trigger function
(Max. meas.,
Deviation meas.,
etc.) |
NG |
NG |
OK |
OK |
Offset
function |
NG |
NG |
OK |
OK |
Zero set
function |
OK |
NG |
OK |
OK |
mm/inch
changeover
function |
NG |
NG |
OK |
OK |
Programing
function |
NG |
NG |
OK(30 kinds) |
OK(9 kinds) |
Graph display |
NG |
NG |
OK |
NG |
Serial port |
OK |
OK |
OK |
OK |
BCD output |
Option |
OK(by LDM-1000BCD) |
RS-485 Function |
Option |
NG |
Cable length |
Standard 5 meters, Max. 30 meters (Extensible to 120m.max. as option) |
Power supply |
AC100-240V Free power supply 50/60Hz |
Power
consumption |
less than 11VA |
less than 14VA |
less than 15VA(only display unit)
less than 8VA(each board) |
Ambient
condition |
Temperature:0-45 degree centigrade, Humidity:35~85%RH(no condensation) |
Outside
dimension |
144(W) * 72(H) * 191(D)[mm] |
216(W) * 144(H) * 225(D)[mm] |
Weight |
Approx. 1.5kg |
Approx. 1.6kg |
Approx. 4kg (only display unit)
Approx. 280g (each board) |